-6-
Fig. 1.4 WM-3500~8500HZD DIMENSIONS
The specifications and dimensions are listed as follows:
Model
CFM
Cellar Size
(cu ft)
Dimensions
W”XD”XH”
Electrical
Weight (lb)
WM-1500HZD
120
90
14.25X16X13.25
115V/60HZ/4A
50
WM-2500HZD
180
200
14.25X16X13.25
115V/60HZ/5A
55
WM-3500HZD
250
650
14.25X21.25X19.75
115V/60Hz/6A
75
WM-4500HZD
250
1000
14.25X21.25X19.75
115V/60Hz/9A
75
WM-6500HZD
500
1500
17X28X22
115V/60Hz/14A 110
WM-8500HZD
500
2000
17X28X22
115V/60Hz/16A 110
NOTES:
•
Also see the voltage, frequency and current specified on the label at the
cooling unit.
•
The rated capacity is determined under the cellar and ambient temperatures
of 55
°
F and 75
°
F with R13 interior and R19 exterior insulations. Any lower
cellar temperature, higher ambient temperature and less insulation will
cause reducing capacity and may not maintain 55
°
F.
•
The ambient temperatures for WM-1500HZD shall not be higher than 78
°
F
or lower than 50
°
F in order to operate properly.
•
The ambient temperatures for WM-2500HZD shall not be higher than 95
°
F
or lower than 50
°
F in order to operate properly.
•
The ambient temperatures for WM-3500~8500HZD shall not be higher than
95
°
F or lower than 50
°
F in order to operate properly.
Summary of Contents for WINE-MATE WM-1500HZD
Page 6: ... 5 Fig 1 2 WM 3500 8500HZD FEATURE DESCRIPTIONS Fig 1 3 WM 1500 2500HZD DIMENSIONS ...
Page 10: ... 9 Fig 2 2 THREAD INSERT Fig 2 3 REAR GASKET ...
Page 11: ... 10 Fig 2 4 TOP EXHAUST GASKET Fig 2 5 COOLING UNIT MOUNTING ...
Page 12: ... 11 Fig 2 6 SECURING BRACKET SCREW ...
Page 13: ... 12 Fig 2 7 CABINET GRILLE ...
Page 25: ... 23 12 Temperature a Low temperature setting a Raise the setting ...
Page 28: ... 26 Fig 6 3 WM 3500 8500HZD WIRING DIAGRAM Fig 6 4 WM 3500 8500HZD WIRING DIAGRAM ALARM CALL ...