-15-
Fig. 2.11 TOP EXHAUST GASKET
Fig. 2.12 WALL GRILLE
4. Cellar Construction
This is only a guide and shall be considered as minimum requirements.
All interior walls and floors shall have a vapor barrier and a minimum of R13
insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum
of R19 insulation. The vapor barrier shall be installed on the warm side of the
insulation. All joints, door frames, electrical outlets or switches and any pipes or
vents that go through the cellar shall be sealed to prevent air and moisture leakage
into the cellar. Concrete, rock, and brick are not insulation or vapor barriers.
Summary of Contents for WINE-MATE WM-1500HZD
Page 6: ... 5 Fig 1 2 WM 3500 8500HZD FEATURE DESCRIPTIONS Fig 1 3 WM 1500 2500HZD DIMENSIONS ...
Page 10: ... 9 Fig 2 2 THREAD INSERT Fig 2 3 REAR GASKET ...
Page 11: ... 10 Fig 2 4 TOP EXHAUST GASKET Fig 2 5 COOLING UNIT MOUNTING ...
Page 12: ... 11 Fig 2 6 SECURING BRACKET SCREW ...
Page 13: ... 12 Fig 2 7 CABINET GRILLE ...
Page 25: ... 23 12 Temperature a Low temperature setting a Raise the setting ...