- 21 -
Troubleshooting
This Troubleshooting Chart is not prepared to replace the training required for a
professional refrigeration service person, not is it comprehensive
Complaint
Possible Causes
Response
1. Unit not
running
a. Power cord not plugged
b. No power from supply
c. Incorrect or loose wirings
d. Low voltage
e. Setting higher than
ambient temperature
f.
Cut-in too high
g. Defrost light blinking
h. Compressor light blinking
i.
Defective controller
a. Check power cord
b. Check receptacle and fuses
c. Check all wirings and connections
d. Contact an authorized electrician
e. Lower temperature setting
f.
Reduce Hy
g. Unit is under defrost mode
h. Unit is under anti-short cycle delay
i.
Call service for diagnosis
2. Unit not
starting , but
temperature
rising high
a. Anti-short cycle
a. Reset AC
3. Temperature
fluctuating
a. Air probe
a. When using an air probe, the wine
bottle
temperature
is
mainly
controlled
by
the
average
air
temperature. If the set-point is 55
°
F
with the differential 4F, the cooling
unit turns on at 59
°
F of air
temperature (It may be higher than
59
°
F if it is in anti-short cycle or
defrost cycle) and turns off at 55
°
F
of air temperature. The average air
temperature is 57
°
F, and then the
wine temperature is around 57+/-
0.5
°
F. The air is light enough to
change so quickly that it maintains
relatively
constant
average
temperature that would prevent wine
bottle temperature from fluctuating.
4. Temperature
high, unit
stopping and
starting
normally
a. Temperature setting high
a. Lower the setting
5. Temperature
high, unit
stopping and
starting with
short running
time
a. Air
probe
touching
the
evaporator
coil,
displaying
temperature ok
b. Short circuit of air flow between
cold-air supply and cellar-air
return, displaying temperature
ok
c. Failed controller and probe
a. Move the air probe away from the
evaporator
b. Deflect the supply air down
c. Call service for diagnosis
6. Temperature
a. Improper cellar insulation & seal
a. Check insulation, gasket and door
Summary of Contents for WINE-MATE WM-1500HZD
Page 6: ... 5 Fig 1 2 WM 3500 8500HZD FEATURE DESCRIPTIONS Fig 1 3 WM 1500 2500HZD DIMENSIONS ...
Page 10: ... 9 Fig 2 2 THREAD INSERT Fig 2 3 REAR GASKET ...
Page 11: ... 10 Fig 2 4 TOP EXHAUST GASKET Fig 2 5 COOLING UNIT MOUNTING ...
Page 12: ... 11 Fig 2 6 SECURING BRACKET SCREW ...
Page 13: ... 12 Fig 2 7 CABINET GRILLE ...
Page 25: ... 23 12 Temperature a Low temperature setting a Raise the setting ...