- 24 -
low
b. Low ambient temperature
c. Air probe fault
d. Temperature controller fault
b. Move to another location
c. Change a new one
d. Change a new one
13.Evaporator
freezing up
a. Evaporator air flow restriction
b. Low temperature setting
c. Low ambient temperature
d. Defective controller or probe
e. Not stopping due to air leak,
high
ambient
temperature,
condenser air flow restriction or
pull-down cooling
f. Initially working then stopping,
moisture in the system
g. Refrigerant low or leaking
h. Capillary tube or expansion
valve blockage
a. Check for fans and air flow
b. Check for set-point
c. Change defrost cycle
d. Check for controller and probe
e. Check for seal, door opening, ambient
temperature and condenser air flow
f. Call service
g. Call service
h. Call service
14.Water leak
a. Air leak in the wine cellar
causing excessive condensate
b. High humidity causing
excessive condensate
c. Evaporator air flow restriction
d. Water passages restricted
e. Drip tray leak (No water
overflow but water leak)
a. Check for air leak
b. Use drain line
c. Check supply air flow or air TD
d. Clean the drip tray
e. Seal the leak using silicone sealant
15.Excessive
condensate in
wine cellar
a. Air leak in the wine cellar
causing excessive condensate
b. High humidity causing
excessive condensate
c. Water passages restricted
a. Check for any air leak
b. Use drain line
c. Clean the drip tray
16.Circuit
tripping
a. Incorrect fuse or breaker
b. Incorrect wirings
c. Failed components
a. Check for proper fuse or breaker
b. Check for wirings and connections
c. Call service
17.Noisy
operation
a. Mounting area not firm
b. Loose parts
c. Compressor overloaded due to
high ambient temperatures or
airflow restriction
d. Defective components
a. Add support to improve installation
b. Check fan blades, bearings, washers,
tubing contact and loose screws.
c. Check for airflow
d. Call service for checking internal
loose, inadequate lubrication and
incorrect wirings
Summary of Contents for WINE-MATE WM-1500HZD
Page 6: ... 5 Fig 1 2 WM 3500 8500HZD FEATURE DESCRIPTIONS Fig 1 3 WM 1500 2500HZD DIMENSIONS ...
Page 10: ... 9 Fig 2 2 THREAD INSERT Fig 2 3 REAR GASKET ...
Page 11: ... 10 Fig 2 4 TOP EXHAUST GASKET Fig 2 5 COOLING UNIT MOUNTING ...
Page 12: ... 11 Fig 2 6 SECURING BRACKET SCREW ...
Page 13: ... 12 Fig 2 7 CABINET GRILLE ...
Page 25: ... 23 12 Temperature a Low temperature setting a Raise the setting ...
Page 28: ... 26 Fig 6 3 WM 3500 8500HZD WIRING DIAGRAM Fig 6 4 WM 3500 8500HZD WIRING DIAGRAM ALARM CALL ...