IRIS Spark Module
To access spark module:
1.
Remove landing ledge
(follow Steps 1-4 of
Landing Ledge section, page 87-91)
.
2.
Disconnect wiring. Remove module from
manifold by pulling forward from burner valve.
3.
Repair/replace module as necessary.
4.
Reverse procedure to reinstall.
Burner Valve
To access burner valve:
1.
Remove main top (
see Main Top Access
section, page 95).
2.
Remove landing ledge
(follow Steps 1-4 of
Landing Ledge section, page 87-91)
.
3.
Remove orifice holders
(See Orifice Holder
section, page 97).
4.
Slide out manifold pipe
(see Steps 3-4 of
Manifold Pipe section, page 98).
5.
Remove spark module
(see Spark Module
section at left).
6.
Remove screw securing valve on bottom of
manifold pipe.
7.
Repair/replace valve as necessary.
8.
Reverse procedure to reinstall.
Service Diagnostics and Procedures–Disassembly
Spark Module
Burner Valve
Spark Module
Burner Valve
Manifold Pipe
Screw
Burner Valve
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect gas supply and electrical power to unit
before servicing. Discharge capacitor through a resistor before attempting to service. Wires removed during
disassembly must be replaced on proper terminals to insure correct earth ground and polarization. After
servicing, reconnect electrical power and gas supply. Before placing appliance into operation, always check
for gas leaks with soapy water solution.
DO NOT
USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
Summary of Contents for VDSC530 Series
Page 124: ...Wiring and Schematics Wiring Schematic VDSC530T 4B 124 2010 Viking Preferred Service ...
Page 125: ... 2010 Viking Preferred Service 125 Wiring and Schematics Wiring Schematic VDSC536T 4G ...
Page 126: ... 2010 Viking Preferred Service 126 Wiring and Schematics Wiring Schematic VDSC536T 4Q ...
Page 127: ... 2010 Viking Preferred Service 127 Wiring and Schematics Wiring Schematic VDSC536T 6B ...