© 2011 Viking Preferred Service
30
Operation
Settings and Functions–Cycle Charts
VDSC548T–Right Oven–
Auto Roast Cycle
VDSC548T–Right Oven–
Defrost Cycle
VDSC548T–Right Oven–
Dehydrate Cycle
VDSC548T - RH
TIME (In Secs)
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
CYCLE: Auto Roast
PHASE
ELEMENTS
Preheat 1
Inner Bake
Preheat 2
Outer Bake
Preheat 3
Inner Broil
Outer Broil
Convection
Conv Fan
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Searing
Inner Bake
Outer Bake
Inner Broil
Outer Broil
Convection
Conv Fan
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Cook
Inner Bake
Outer Bake
Inner Broil
Outer Broil
Convection
Conv Fan
11 amps
10 Seconds
20 Seconds
30 Seconds
40 Seconds
50 Seconds
60 Seconds
NOTE: Convection fan is running at
HIGH
speed. Motor changes direction.
15.2 amps
15.2
11 amps
15.2
VDSC548T - RH
TIME (In Secs)
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
CYCLE: DEFROST
PHASE
ELEMENTS
Inner Bake
Outer Bake
Inner Broil
Outer Broil
Convection
Conv Fan
6.5 Amps
10 Seconds
20 Seconds
30 Seconds
40 Seconds
50 Seconds
60 Seconds
NOTE: Convection fan is running at
Low
speed. Motor changes direction.
NO HEATING ELEMENTS UTILIZED
VDSC548T - RH
TIME (In Secs)
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
CYCLE: DEHYDRATE
PHASE
ELEMENTS
Inner Bake
Outer Bake
Inner Broil
Outer Broil
Convection
Conv Fan
90°
6.5 Amps
10 Seconds
20 Seconds
30 Seconds
40 Seconds
50 Seconds
60 Seconds
NOTE: Convection fan is running at
Low
speed. Motor changes direction.
Summary of Contents for VDSC530 Series
Page 124: ...Wiring and Schematics Wiring Schematic VDSC530T 4B 124 2010 Viking Preferred Service ...
Page 125: ... 2010 Viking Preferred Service 125 Wiring and Schematics Wiring Schematic VDSC536T 4G ...
Page 126: ... 2010 Viking Preferred Service 126 Wiring and Schematics Wiring Schematic VDSC536T 4Q ...
Page 127: ... 2010 Viking Preferred Service 127 Wiring and Schematics Wiring Schematic VDSC536T 6B ...