2.2 Specification
Oil boiler, types B and C for operation with low sulphur fuel oil to DIN 51603-1 EL
Rated output
12.9/19.3
16.1/23.5
Rated output/burner stage
Burner stage 1
Burner stage 2
Burner stage 1
Burner stage 2
T
V
/T
R
= 50/30 °C
kW
12.9
19.3
16.1
23.5
T
V
/T
R
= 80/60 °C
kW
12
18
15
22
DHW heating
kW
12
18
15
22
Rated heat input
kW
12.5
18.7
15.6
22.9
CE designation
CE-0035BM112
DIBt approval
Z-43.11-153
IP rating
IP 20 to EN 60529
Power consumption
(incl. circulation pump)
W
200
270
200
270
Weight
kg
170
170
170
170
Heat exchanger capacity
l
12
12
12
12
Heating water flow rate
with 200 mbar residual head
l/h
1060
1060
1060
1060
Max. flow rate
(limit for the use of hydraulic separation)
l/h
1390
1390
1390
1390
Nominal circulation water volume
at ΔT = 20 K
l/h
774
774
774
774
Expansion vessel
Capacity
l
12
12
12
12
Pre-charge pressure
bar
0.75
0.75
0.75
0.75
Permiss. operating pressure
bar
3
3
3
3
Safety valve connection
R (female
thread)
¾
¾
¾
¾
Dimensions
Length
mm
582
582
582
582
Width
mm
600
600
600
600
Height
mm
1600
1600
1600
1600
Suction and return line
on the oil hoses
R (female
thread)
⅜
⅜
⅜
⅜
Motor speed
Oil pump drive
min
-1
2880
2880
2880
2880
Capacity
Oil pump
l/h
45
45
45
45
DHW cylinder
Capacity
litres
130
130
Permiss. operating pressure (DHW side)
bar
10
10
Continuous DHW output
kW
18
22
for heating DHW from 10 to 40 °C
l/h
516
631
Performance factor N
L
*2
to DIN 4708
1.6
1.6
Max. draw-off rate (over a 10 minute
period)
for the stated performance factor N
L
and
DHW heating from 10 to 45 °C
l/min
17.3
17.3
Flue gas parameters
*3
Temperature (at return temp. 30 °C)
°C
34
35
39
40
Temperature (at return temp. 60 °C)
°C
67
67
72
72
Mass flow rate
kg/h
19.3
28.8
24.5
35.9
Available draught
Pa
100
100
100
100
mbar
1.0
1.0
1.0
1.0
Standard seasonal efficiency [to DIN]
at
T
V
/T
R
= 50/30 °C
%
up to 98 (H
s
)/104 (H
i
)
Average condensate volume
at T
V
/T
R
= 50/30 °C
l/day
3-6
3-6
3-6
3-6
Condensate connection
Hose ferrule
Ø mm
20-24
20-24
20-24
20-24
*2
At 70 °C average boiler water temperature and cylinder storage temperature Tcyl = 60 °C.
The performance factor NL changes with the cylinder storage temperature Tcyl.
Standard values: Tcyl = 60 °C
→
1.0 × NL Tcyl = 55 °C
→
0.75 × NL Tcyl = 50 °C
→
0.55 × NL Tcyl = 45 °C
→
0.3 × NL.
*3
Calculation values for sizing the flue gas system to EN 13384.
Flue gas temperatures measured as gross values at 20 °C combustion air temperature.
The flue gas temperature at a return temperature of 30 °C is significant for the sizing of the flue gas system.
The flue gas temperature at a return temperature of 60 °C is used to determine the application range of flue pipes with max. permissible
operating temperatures.