3.6 Vitocell 100-W, adjacent (type CVUA – 300 litre, white finish), made from steel with
Ceraprotect enamel coating, for dual mode DHW heating
■ Adjacent
■ Made from steel, with Ceraprotect enamel coating and internal indi-
rect coils
■ for dual mode DHW heating
■ with Solar-Divicon, integral pipework and solar control module, type
SM1.
For further technical details, see separate datasheet for the Vitocell 100-U.
Capacity
l
300
DIN register no.
0266/07-13 MC/E
Connections
Heating water flow and return
R
1
DHW and cold water
R
1
DHW circulation
R
1
Permiss. operating pressure
– heating water, solar and DHW side
bar
10
Permiss. temperatures
– heating water side
ºC
160
– solar side
ºC
110
– DHW side
ºC
95
Standby heat loss
(standard parameter)
kWh/24 h
1.00
q
BS
at 45 K temp. differential
Dimensions
Length (Ø)
mm
631
Width
mm
780
Height
mm
1705
Height when tilted
mm
1790
Weight
including thermal insulation
kg
179
Total weight in operation
kg
481
SPR1
844
343
b
a
c
1601
1356
1116
996
761
261
77
WW/HVs/HRs
VA
KW/E
TH
TE
SPR2
HV/SPR1
Z
HR
HVs
HRs
86
86
A
E
Drain
HR
Heating water return
(upper indirect coil)
HRs
Heating water return, solar (lower indirect coil; fit the cylinder
temperature sensor into the solar heating water return (HRs)
using the threaded elbow with sensor well SPR2 from the
standard delivery)
HV
Heating water flow (upper indirect coil)
HVs
Heating water flow, solar (lower indirect coil)
KW
Cold water
SPR1 Cylinder temperature control sensor
SPR2 Solar thermal system cylinder temperature sensor
TE
Sensor well for lower thermometer
TH
Thermometer
VA
Protective magnesium anode
WW
DHW to the pipework
Z
DHW circulation
A
Lower indirect coil (solar)
The connections HVs and HRs are located at the top of the
DHW cylinder
Separate DHW cylinder for the Vitoladens 300-W
(cont.)
24
VIESMANN
VITOLADENS 300-W
/
VITOLADENS 333-F
3
5822 425 GB