142
398
A
B
C
HV
HR
98
120
D
G 1½
a
b
HV
HR
Divicon without mixer (wall mounting, shown without thermal insula-
tion)
HR Heating return
HV Heating flow
A
Overflow valve (accessory for multi-stage circulation pump)
B
Ball valves with thermometer (as programming unit)
C
Circulation pump
D
Ball valve
Heating circuit connec-
tion
R
¾
1
1¼
Flow rate (max.)
m
3
/h
1.0
1.5
2.5
a (female)
Rp
¾
1
1¼
a (male)
G
1¼
1½
2
b (female)
Rp
¼
1
1¼
b (male)
G
1¼
1¼
2
Installation example: Divicon with triple manifold
HV
HR
120
120
120
b
a
d
c
180
180
HV
HR
(shown without thermal insulation)
HR Heating return
HV Heating flow
Dimensions
Manifold with heating circuit connection
R ¾ and R 1
R 1¼
a
135
183
b
535
583
c
784
784
d
G 1¼
G 2
Installation accessories
(cont.)
32
VIESMANN
VITOLADENS 300-W
/
VITOLADENS 333-F
4