Control Technology
29
Outdoor Reset Programming Unit
(continued)
Heating system types
(continued)
System type 4 or 5
(with or without low-loss header)
Heating system with one heating circuit without mixing valve, one heating
circuit with mixing valve, with/without domestic hot water heating.
Coding address “00:5” Without DHW heating
Coding address “00:6” With DHW heating
System type 6
(with or without low-loss header)
Heating system with two heating circuits with mixing valve (one LON, one
KM-BUS controlled), with/without domestic hot water heating.
Coding address “00:3” Without DHW heating
Coding address “00:4” With DHW heating
System type 7
(with or without low-loss header)
Heating system with one heating circuit without mixing valve, one heating
circuit with mixing valve and system separation, with/without domestic hot
water heating.
Coding address “00:5” Without DHW heating
Coding address “00:6” With DHW heating
System type 8
Heating system with multiple heating circuits with mixing valves, low-loss
header and with/without domestic hot water heating (two LON, one KM-BUS
controlled).
Coding address “00:3” Without DHW heating
Coding address “00:4” With DHW heating
System type 9
(see Vitocontrol-S, WB2B multiple-boiler control Installation/
Service Instructions)
Multiple-boiler heating system with multiple heating circuits with mixing
valves, low-loss header and domestic hot water heating.