Control Technology
32
Outdoor Reset Programming Unit
(continued)
Room temperature setpoint adjustment
Standard Room Temperature
A
Boiler water temperature / Supply
temperature in ºC
B
Outdoor temperature in ºC
C
Room temperature setpoint in ºC
D
Heating circuit pump “OFF”
E
Heating circuit pump “ON”
1.
Press “
⊕
”.
“1
r
r
r
r
“
flashes on the
display.
2.
Press
“
”
to select a heating circuit
without a mixing valve
or
3.
Press “
⊕
”.
“2
r
r
r
r
“
flashes on the
display.
4.
Press
“
”
to select a heating circuit
with mixing valve.
5.
Adjust the day temperature setpoint
with rotary selector “
ts
“. The value
will automatically be accepted after
approx. 2 sec. The heating curve will
be adjusted accordingly along the
room temperature setpoint axis
C
,
which results in modified start/stop
characteristics of the heating circuit
pumps if the heating circuit pump
logic is enabled.
Temperature conversion:
˚
C
˚
F
-20
-4
20
68
26
79
90
194
Room Temperature Setback
A
Boiler water temperature / Supply
temperature in ºC
B
Outdoor temperature in ºC
C
Room temperature setpoint in ºC
D
Heating circuit pump “OFF”
E
Heating circuit pump “ON”
1.
Press “
⊕
”.
“1
r
r
r
r
“
flashes on the
display.
2.
Press
“
”
to select a heating circuit
without a mixing valve
or
3.
Press “
⊕
”.
“2
r
r
r
r
“
flashes on the
display.
4.
Press
“
”
to select a heating circuit
with a mixing valve.
5.
Press “
tm
” for night temperature
setback.
6.
Press “
⊕
/
“ to change value.
7. “
”
to confirm value.
Temperature conversion:
˚
C
˚
F
-20
-4
5
41
14
57
20
68
90
194
5
4
4
3
2
0
7
v
1
.5
90
-20
D
E
A
C
B
Fig. 18
Example 1: Adjusting the
room temperature setpoint
from 20 to 26ºC
90
-20
D
E
A
C
B
Fig. 19
Example 2: Adjusting the
room temperature setback
from 5 to 14ºC