Coding
37
Coding Level 1
Accessing coding level 1
Note:
H
All codes are displayed as plain text.
H
Codes that are irrelevant due to the system equipment level or the setting of
other codes will not be displayed.
H
Heating systems with one heating circuit without mixing valve
*1
and one
heating circuit with mixing valve
*2
:
Initially, coding addresses ”A0” to ”d4” for the heating circuit without a mixing
valve are scanned; then the coding addresses for the heating circuit with a
mixing valve are scanned.
1.
Press “
9
” +
“
w
“ simultaneously
for approx. 2 sec.
2.
Press
“
⊕
/
“ for the required
coding address, the address flashes.
3.
Press
“
”.
to confirm.
4. “
⊕
/
“ for the selected value.
5. “
”.
to confirm. The display
briefly shows ”accepted” and the
address flashes again.
6. “
⊕
/
“ to select other addresses
.
7.
Press “
9
” +
“
w
“ simultaneously
for approx. 1 sec. Coding level 1 is
terminated.
*1
May also be referred to as “heating circuit without mixer A1”
.
*2
May also be referred to as “heating circuit with mixer M2”.