64
Power-OFF with on-site load disconnection
The power-OFF signal is connected to
the on-site contactor of the economy tar-
iff power supply and in the heat pump
control unit. The compressor
and
instan-
taneous heating water heater (if instal-
led) are "forced" off when power-OFF is
enabled.
The instantaneous heating water heater
cannot be switched on during power-
OFF; parameter
"Output for instant.
heating water heater at power-OFF
790A"
has no effect.
Note
Observe the technical connection condi-
tions of the relevant power supply util-
ity.
≈
3
3
4
4
3
3/N
3/N
4
kWh
kWh
3
7
5 (400 V~)
(230 V~)
X3.7
X3.6
X3.18/X2.1/X1.1
Diagram excluding fuses and RCD
A
Heat pump control unit (internal unit,
luster terminals, see chapter "Over-
view of connections: Internal unit")
B
Instantaneous heating water heater
(if installed)
C
Heat pump compressor (external
unit)
D
Heat pump control unit power sup-
ply (see chapter "Heat pump control
unit power supply (230 V~)")
E
High tariff meter
F
Backup fuse ripple control receiver
Installation sequence
Power supply
(cont.)
5600 950 GB