127
Type AWT-AC
221.A04
221.A07
221.A10
221.A13
Air intake temperature
Cooling mode
■ Min.
°C
15
15
15
15
■ Max.
°C
45
45
45
45
Heating mode
■ Min.
°C
–15
–15
–15
–15
■ Max.
°C
35
35
35
35
Heating water
at 10 K spread
Capacity
l
16.7
16.7
17.7
17.7
Minimum flow rate
(always maintain)
l/h
600
820
1200
1380
Max. external pressure
drop (RFH) at min. flow
rate
mbar
590
540
440
380
Max. flow temperature
°C
55
55
55
55
Electrical values
External unit
■ Rated voltage, com-
pressor
1/N/PE 230 V/50 Hz
■ Max. rated current,
compressor
A
5
9
10
15
■ Starting current,
compressor
A
10.5
15
10
10
■ Compressor starting
current with stalled
armature
A
20
25
25
32
■ Starting current
(charging DC capaci-
tors)
A
45
< 35
30
30
■ Internal fuse/MCB
A
3.5
3.5
3.15
3.15
■ IP rating
IP
24
24
24
24
Specification
Specification
(cont.)
5600 950 GB
Service