Low voltage connecting cables
(sensors, KM BUS) <42 V
D
Type AWT-AC 221.A10
and
A13
:
12 V BUS cable: Routing in the
230 V~ voltage area (for connection,
see page 58)
E
Type AWT-AC 221.A04
and
A07
:
43 V BUS cable: Routing in the
230 V~ voltage area (for connection,
see page 58)
F
Heat pump control unit power cable
230 V~
Overview of connections: Internal unit
Note
■ Route 230 V~ cables and LV cables
separately and bundle them tightly
together at the terminals. This ensures
that, in case of failure, for example
when detaching a wire, the wires can-
not drift into the adjacent voltage area.
■ Strip the insulation as close to the ter-
minals as possible.
■ If two components are connected to
the same terminal, press both wires
together into a single wire ferrule.
Installation sequence
Electrical connection
(cont.)