128
Type AWT-AC
221.A04
221.A07
221.A10
221.A13
Electrical values
Internal unit
Heat pump control
unit/PCB
■ Rated voltage, con-
trol unit/PCB
1/N/PE 230 V/50 Hz
■ Fuse protection,
power supply
1xB16A
■ Internal fuse/MCB
6.3A (slow)/250 V
Instantaneous heat-
ing water heater
■ Rated voltage
1/N/PE 230 V/50 Hz
3/N/PE 400 V/50 Hz
■ Heating output
kW
8.8
8.8
8.8
8.8
■ Fuse protection,
power supply
3xB16A
3xB16A
3xB16A
3xB16A
Electrical power con-
sumption
■ Fan (max.)
W
65
70
130
130
■ External unit (max.)
W
3.0
3.6
5.8
5.8
■ Secondary pump at
stage 3/2/1
W
132/92/62
132/92/62
132/92/62
132/92/62
■ Control unit/PCB,
external unit (max.)
W
150
150
150
150
■ Control unit/PCB,
internal unit (max.)
W
5
5
5
5
■ Max. rating, control
unit/PCB
W
1000
1000
1000
1000
Refrigerant circuit
Refrigerant
R410A
R410A
R410A
R410A
Filling capacity
kg
1.2
2.15
2.95
2.95
Top-up amount for line
lengths >12 m to
≤
30 m
g/m
20
60
60
60
Compressor (hermeti-
cally sealed)
Type
Rotating
piston
Rotating
piston
Scroll
Scroll
Permiss. operating
pressure
■ High pressure side
bar
MPa
43
4.3
43
4.3
43
4.3
43
4.3
■ Low pressure side
bar
MPa
43
4.3
43
4.3
43
4.3
43
4.3
Specification
Specification
(cont.)
5600 950 GB