A
Plug from the pack
B
Distributor (on-site)
C
Cylinder primary pump
D
Two-way valve (normally closed,
tQ
see page 53)
1.
Route the connecting cable of the
cylinder primary pump through the
strain relief at the front of the con-
trol panel.
2.
Connect the cylinder primary pump
cable and the two-way valve, in
accordance with the illustration,
with the 3-pin plug with the contact
designation PE, 7, 8 (in the pack).
3.
Undo the four screws and lift out
the control panel upwards.
4.
Fit the connecting cable in front
position to mating plugs on top-hat
rail marked PE, 7 and 8 (con-
necting area X50).
5.
Re-insert the control panel and
secure with the four screws.
Making the electrical connections of the cylinder . . .
(cont.)
61
Installation sequence
55
92
968
GB
Installation