This setting determines, after what "value" (integral comprising the duration and
level of a temperature deviation from the set control temperature) the electric
heating is switched ON. Brief temperature deviations will not cause the electric
heating to be switched ON.
A
Set control temperature
B
Actual temperature
C
"
Hysteresis flow
" (see page 146)
D
"Value" (integral comprising the
duration and level of a tempera-
ture deviation)
Access
&
"
Device settings
"
&
"
Programming
"
&
"
Electric heater
"
&
"E heating threshold"
(
P
/
Q
)
Standard setting
300 K · min
Setting range
10 to
30000 K · min
Maximum stage; electric heater
This setting determines, with what output (stage 1, 2 or 3, see from page 195)
DHW and heating water will be boosted.
Access
&
"
Device settings
"
&
"
Programming
"
&
"
Electric heater
"
&
"Max. stage E heating"
(
l
/
m
)
Standard setting
3
Setting range
1 to 3
Electric heating threshold