122
Type AWT-AC
241.A04
241.A05
241.A07
241.A10
241.A13
Connections
Heating water flow
mm
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Heating water return
mm
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Cold water
Rp
¾
¾
¾
¾
¾
DHW
Rp
¾
¾
¾
¾
¾
DHW circulation
G
1
1
1
1
1
Solar circuit flow
DN 20 pipe sleeve for multi connect system
Solar circuit return
DN 20 pipe sleeve for multi connect system
Liquid line
■
Pipe
7
mm
6 x 1
10 x 1
10 x 1
10 x 1
10 x 1
■
Internal unit
UNF
⅝
⅝
⅝
⅝
⅝
■
External unit
UNF
⁷
⁄
₁₆
⅝
⅝
⅝
⅝
Hot gas line
■
Pipe
7
mm
12 x 1
16 x 1
16 x 1
16 x 1
16 x 1
■
Internal unit
UNF
⅞
⅞
⅞
⅞
⅞
■
External unit
UNF
¾
⅞
⅞
⅞
⅞
Max. line length, liquid line, hot
gas line
m
20
30
30
30
30
Sound power of external unit
at rated
heating output
(measurements with reference to EN 12102/
EN ISO 9614-2)
Weighted total sound power level
■
At A7
±
3 K
/W35
±
5 K
dB(A)
60
62
62
62
63
■
At A7
±
3 K
/W55
±
5 K
in night mode dB(A)
58
58
58
60
60
Energy efficiency class
to EU
Regulation no. 811/2013
Heating, average climatic condi-
tions
■
Low temperature applications
(W35)
A
++
A
++
A
++
A
++
A
++
■
Medium temperature applica-
tions (W55)
A
+
A
+
A
+
A
++
A
+
DHW heating
■
Draw-off profile L
A
A
A
■
Draw-off profile XL
A
A
400 V appliances
Type AWT-AC
241.B10
241.B13
241.B16
Heating output data
to EN 14511
(A2/W35)
Rated heating output
kW
7.57
9.06
11.2
Fan speed
rpm
600
690
690
Power consumption
kW
2.00
2.42
3.45
Coefficient of performance
ε
(COP) in heating mode
3.79
3.72
3.20
Output control
kW
2.73 to 10.92
3.30 to 12.29
—
Specification
Specification
(cont.)
5700 582 GB
Appendix