114
Parameters
Code
Delivered condition Commission-
ing
Maintenance/
service
"Temperature sensor at bottom of DHW
cylinder"
600E
0
"Enable booster heaters for DHW heat-
ing"
6014
0
"Enable electric heaters for DHW heat-
ing"
6015
1
"Priority DHW heating with combi cylin-
der"
6016
0
"Start attempts for DHW after high pres-
sure shutdown"
6017
1
Solar
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
"Type solar control unit"
7A00
0
"Max. collector temperature"
7A01
1300 (
≙
130 °C)
"Start hysteresis solar circuit pump"
7A02
70 (
≙
7 K)
"Stop hysteresis solar circuit pump"
7A03
30 (
≙
3 K)
"Flow rate solar circuit for calculating so-
lar yield"
7A07
100 l/h
"Display message incorrect circulation"
7A09
1
Electric booster heater
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
Service
"Enable instantaneous heating water
heater"
7900
1
"Enable electric heaters for DHW heat-
ing"
7901
0
"Enable instant. heating water heater for
central heating"
7902
0
"Max. output instantaneous heating wa-
ter heater"
7907
3
"Output for instant. heating water heater
at power-OFF"
790 A
0
"Dual mode temp instant. heating water
heater"
790 B
500 (
≙
50 °C)
Internal hydraulics
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
Service
"Heat pump for drying a building"
7300
0
"Time program for screed drying"
7303
0
"Flow temperature for external demand"
730C
500 (
≙
50 °C)
"Starting time high efficiency circulation
pump"
7365
Do not adjust
Commissioning/service reports
Control parameters report
(cont.)
5700 582 GB
Appendix