14
!
Please note
Impacts, compression and tensile loads can
cause damage to the outside panels of the
appliance.
Never
apply loads/weight to the top, front or
side panels of the appliance.
Installation room requirements
!
Please note
Unfavourable ambient conditions can lead to
malfunction and appliance damage.
■
The installation room must be dry and free
from the risk of frost.
■
Ensure ambient temperatures between 0 and
35 °C.
Danger
Dust, gases and vapours can be damaging to
health and cause explosions.
Avoid dust, gases and vapours in the installation
room.
!
Please note
Overloading the floor can result in damage to
the building structure.
Observe the permissible floor load. Take the
total weight of the appliance into account.
Total weight with filled DHW cylinder
Type AWT/AWT-AC
Weight in kg
241.A04
424
241.A05
424
241.A07
424
241.A10
427
241.A13
427
241.B10
427
241.B13
427
241.B16
427
Minimum room volume (to EN 378):
Type AWT/AWT-AC
Minimum room volume in m
3
241.A04
2.7
241.A05
4.9
241.A07
4.9
241.A10
6.1
241.A13
6.1
241.B10
6.1
241.B13
6.1
241.B16
6.1
Installation sequence
Installing the internal unit
(cont.)
5700 582 GB
Installation