124
Type AWT-AC
241.B10
241.B13
241.B16
External unit electrical values
■
Rated voltage, compressor
3/N/PE 400 V/50 Hz
■
Max. operating current, com-
pressor
A
7.85
9.89
13.09
■
Starting current, compressor
A
10
10
10
■
Starting current, compressor
with stalled armature
A
16
16
16
■
MCB/fuse protection
A
16
16
16
■
IP rating
IP
X4
X4
X4
Internal unit electrical values
Heat pump control unit/PCB
■
Rated voltage, control
unit/PCB
1/N/PE 230 V/50 Hz
■
MCB/fuse protection, power
supply
1 x B16A
■
Internal fuse
6.3 A (slow)/250 V
Instantaneous heating water
heater
■
Rated voltage
1/N/PE 230 V/50 Hz
3/N/PE 400 V/50 Hz
■
Heating output
kW
8.8
8.8
8.8
■
MCB/fuse protection, power
supply
3 x B16A
3 x B16A
3 x B16A
Electrical power consumption
■
Fan (max.)
W
130
130
130
■
External unit (max.)
kW
5.0
6.3
6.3
■
Secondary pump (PWM)
W
3 to 50
3 to 50
3 to 50
■
Control unit/PCB, external unit
(max.)
W
150
150
150
■
Control unit/PCB, internal unit
(max.)
W
5
5
5
■
Max. rating, control unit/PCB
W
1000
1000
1000
Refrigerant circuit
Refrigerant
R410A
R410A
R410A
■
Refrigerant charge
kg
2.95
2.95
4.2
■
Global warming potential
(GWP)
2088
2088
2088
■
CO
2
equivalent
t
6.20
6.20
6.20
■
Top-up amount for line lengths
>
12 m to
≤
30 m
g/m
60
60
60
Compressor (hermetically
sealed)
Type
Double rotating pis-
ton
Double rotating pis-
ton
Double rotating pis-
ton
Permiss. operating pressure
■
High pressure side
bar
MPa
43
4.3
43
4.3
43
4.3
■
Low pressure side
bar
MPa
43
4.3
43
4.3
43
4.3
Specification
Specification
(cont.)
5700 582 GB
Appendix