73
Overview of electrical components
See from page 29.
Overview of internal components, type BW 301.BS090 to BW 302.BS250
432
6
qP 9 qW
qW qQ
1
qE
qU
qR qTqZ
wQ
3
2
wP
qT
qZ
qU
4
6
5
7
8
qI
qO
wW
Fig.60
1
Wiring chamber
2
Safety high pressure switch, high pressure 1 (stage 1)
3
Only type BW 302.B090, BW 302.B120, BW 302.B150, BW 302.B180 and BW 302.B250:
Safety high pressure switch, high pressure 2 (stage 2)
4
High pressure sensor EEV
5
Suction gas temperature sensor EEV
6
Low pressure sensor EEV
7
Liquid gas temperature sensor EEV
8
Electronic expansion valve EEV
9
Only type BW 302.B090, BW 302.B120, BW 302.B150, BW 302.B180 and BW 302.B250:
Hot gas temperature sensor/compressor 2 (stage 2)
qP
Only type BW 302.B090, BW 302.B120, BW 302.B150, BW 302.B180 and BW 302.B250:
Compressor 2 (stage 2)
Hot gas temperature sensor/compressor 1 (stage 1)
qW
Compressor 1 (stage 1)
qE
Sight glass, oil level, compressor 1 and 2
qR
Secondary circuit return temperature sensor
qT
Filter dryer
qZ
Only type BW 302.B090, BW 302.B120, BW 302.B150, BW 302.B180 and BW 302.B250:
Second parallel filter dryer
qU
Condenser
qI
Evaporator
qO
Primary circuit return temperature sensor (heat pump brine outlet)
wP
Secondary circuit flow temperature sensor
wQ
Primary circuit flow temperature sensor (heat pump brine inlet)
wW
Secondary circuit return temperature sensor
Troubleshooting
Repairs
5549 991 GB
Service
Summary of Contents for 301.BS090