66250010-EN - V2.0 - 24/09/18
- 17 -
Telephone Interface Module
Art. 380N/UK Telephone Interface Module - Installation Instructions
Programming the Art.380N/UK
DISABLE ** MODE
An alternative to using
**
to enter programming is to use the
RECALL
button on the telephone (pressed twice i.e.
RECALL,
RECALL
) or pressing the hook switch on the telephone twice in
succession.
Code
** Status
17 0
Enabled (default)
17 1
Disabled
This method of accessing the programming menu really only applies if an older style telephone is used with the
Art.380N/UK
. In
most cases it is recommended that the
**
command is left in default mode (remains enabled) as most modern telephones either use
the
RECALL
button to recall the last number that was called or they no longer have a
RECALL
button at all.
IMPORTANT NOTE: In the event that the ** command is inadvertently disabled it is recommended that the 'hard-wired' reset
procedure is followed, as described on page 13, in order to reset the Art.380N/UK back to factory defaults so the ** command
is reinstated.
DIRECT DTMF READING
This feature allows the
DTMF
tones from the telephone to be
read by the
Art.380N/UK
during a call without first pressing
**
.
Use the following codes in the table to enable or disable the
DTMF
tone reading. By default this mode is enabled.
Code
DTMF Reading
18 0
Disabled
18 1
Enabled (default)
REASSURANCE TONE SETUP
This feature allows the
Art.380N/UK
to generate a reassurance
tone through the speaker at the door station to indicate to the
caller that a call has been placed.
Use the following codes in the table to enable or disable the
reassurance tone. By default this mode is disabled.
Code
Reassurance Tone Status
34 0
Disabled
34 1
Enabled (default)
TONE DETECTION
This feature allows the
Art.380N/UK
to detect normal telephone
line tones such as
busy
,
no answer
,
call end etc
. Sometimes,
however, it may be necessary to disable this feature to avoid
false detection. Use the following codes in the table to enable or
disable the tone detection. By default this mode is enabled.
Code
Tone Detection Status
26 0
Disabled
26 1
Enabled (default)
AT HOME CONTROL
This feature allows the 'divert call' to be automatically switched
OFF
when active simply by picking up one of the handsets on
the output of the
Art.380N/UK
and then replacing it. Use the
following codes in the table to enable or disable this feature. By
default this mode is disabled.
Code
At Home Control Status
30 0
Enabled
30 1
Disabled (default)
SPEECH ADJUSTMENTS
The speech volume control of the system that the
Art.380N/UK
is connected to can be adjusted in both directions using the control
POTs on the entrance panel speaker unit: mic
, speaker
and depending on the panel an additional balance POT
.
Additionally the speech volume towards the entrance panel can be adjusted electronically via the telephone connected to the
Art.380N/UK
using the following procedure:
1. Lift the telephone handset and press
**371
to enter programming (remember to listen for the double confirmation
beep);
2. Press
27 X
, where
X
= a volume level between
1
to
9
,
1
being the lowest volume and
9
being the maximum volume, by
default the volume level is set to
5
(again listen for the double confirmation beep);
3. Replace the telephone handset and make a test call to check the speech volume.
Alternatively the speech volume towards the panel can also be adjusted when the speech is open between the panel and the
telephone during a live call following step 2 described above.
Speech volume adjustments can also be made using the balance POT located on the top side of the
Art.380N/UK
. This balance POT
is a particularly useful adjustment control when the
Art.380N/UK
is in divert call mode and the level of speech from the entrance
panel to the telephone called is low (also refer to
Art.380N/UK
balance POT adjustment on page 5).