Telephone Interface Module
Art. 380N/UK Telephone Interface Module - Installation Instructions
Programming the Art.380N/UK
DIAL IN FACILITY SETUP
The dial in facility can be used to allow a caller from an outside telephone line to dial into the
Art.380N/UK
and access the functions
available. For example this could be to open the door or activate an auxiliary output.
ENABLING / DISABLING THE DIAL IN FACILITY
To setup the dial in facility use one of the following codes shown
in the table. By default his facility is disabled.
Code
Dial In Facility Status
12 0
Disabled (default)
12 1
Enabled
DIAL IN ANSWER AFTER A NUMBER OF RINGS
The
Art.380N/UK
can count the number of rings before it
activates and takes hold of the call. This can be set from as little
as 1 ring up to a maximum of 10 rings. To setup the number of
rings use one of the following codes shown in the table.
IMPORTANT NOTE: A standard BT line telephone ring is a
double ring and therefore counts as two rings.
Code
Rings
Code
Rings
25 1
1
25 6
6
25 2
2
25 7
7
25 3
3
25 8
8
25 4
4
25 9
9
25 5
5
25 0
10
DIAL IN TIME / DIVERT TIME
The dial in time / divert time is the maximum time that a call
will last before clearing down (hanging up) and releasing the
telephone line. The dial in time / divert time can be set from 30
seconds up to a maximum of 300 seconds (5 minutes).
To setup the dial in time / divert time use one of the following
codes shown in the table.
Code
Time (secs)
Code
Time (secs)
24 1
30
24 6
180
24 2
60
24 7
210
24 3
90
24 8
240
24 4
120
24 9
270
24 5
150
24 0
300
DIVERT CALL SETUP
The divert facility allows a call to be diverted to another telephone number. When in divert mode it is recommended that you use
a 4 digit access code to restrict the functions of the
Art.380N/UK
to authorised callers (also refer to access code setup on page 16).
PROGRAMMING A DIVERT TELEPHONE NUMBER
To program a divert telephone number use the programming
command shown in the table. The telephone number stored can
be a minimum of 3 digits and a maximum of 40 digits in length.
Code
Description
321
n
#
where n = the telephone number to divert to
IMPORTANT NOTE: When programming the divert telephone number remember to include the # after the telephone number
otherwise the Art.380N/UK will not accept the programming command.
ALTERNATE BETWEEN LOCAL CALL MODE AND DIVERT MODE
When in local call mode and a call is placed, the
Art.380N/UK
will only ring the telephone connected into the master socket
wired from
T1
and
T2
. When in divert mode and a call is placed,
the
Art.380N/UK
will only ring the divert telephone number that
is stored without calling the local telephone connected into the
master socket.
Code
Mode
11 1
Divert mode
11 0
Local call mode (default)
To switch between the 2 modes use one of the codes shown in
the table above.
DIVERTING THE CALL AUTOMATICALLY AFTER A PRESET NUMBER OF SECONDS
When this mode is enabled, the telephone in the property
(connected into the master socket) will ring for the number of
seconds programmed and if after this period the call is still not
answered, it will divert to the pre-programmed divert telephone
number.
To set the time before diverting use one of the following codes
shown in the table. By default this feature is disabled.
Code
Time (secs)
Code
Time (secs)
35 1
4
35 6
24
35 2
8
35 7
28
35 3
12
35 8
32
35 4
16
35 9
36
35 5
20
35 0
Disabled