66250010-EN - V2.0 - 24/09/18
- 13 -
Telephone Interface Module
Art. 380N/UK Telephone Interface Module - Installation Instructions
Door open time
22 X
X = 0 to 9
(
0
= 1 second,
1
-
9
multiplied by 2, i.e. if
X
= 3 then time =
6 seconds; if
X
= 4 then time = 8 seconds).
3
14
Door open key
23 X
X = 0, 8 or 9.
0
14
Divert call/ dial in time
24 X
X = 0 to 9
(
X
multiplied by 30 seconds = time, i.e. if
X
= 2 then time =
60 seconds; if
X
= 4 then time = 120 seconds).
2
15
Dial in answer after a
number of rings
25 X
X = 0 to 9
(
0
= 10 rings,
1
-
9
= number of rings before automatically
answering).
5
15
Tone detection
26 X
X = 1 or 0
(
1
to enable tone detection and
0
to disable tone detection).
1
17
Speech volume towards
the entrance panel
27 X
X = 1 to 9
(
1
= lowest volume and
9
= maximum volume).
5
17
A1 auxiliary output
control
28 X
X = 1 or 0
(
1
for momentary trigger and
0
for latching trigger).
1
14
A2 auxiliary output
control
29 X
X = 1 or 0
(
1
for momentary trigger and
0
for latching trigger).
1
14
At home control
30 X
X = 1 or 0
(
1
to disable home control and
0
to activate home control).
1
17
Access code
31 XXXX X = 4 digit access code
(note that this code must begin with either
1, 2, 3 or 4).
no code
16
Divert phone number
321 n # n = telephone number
(e.g. to program the number
0123 456789
would be
321 0123456789#
, always confirm the number with the
#
key at the end. A minimum of 3 digits can be used for the number).
N/A
15
Revert to default settings
(reset)
33 1111
Resets all settings back to factory default.
N/A
13
Reassurance tone at the
door panel
34 X
X = 1 or 0
(
1
to activate the reassurance tone and
0
to deactivate the
reassurance tone).
0
17
Divert to number after n
seconds
35 X
X = 0 to 9
(
0
to disable the divert and
1 - 9
multiplied by 4 = time, i.e.
if
X
= 3 then time = 12 seconds before automatic divert).
0
15
Divert mode audio
automatically
ON/OFF
36 X
X = 1 or 0
(
1
to manually open the speech by pressing
2
after
answering the call and
0
to enable the speech automatically).
0
16
PROGRAMMING AND USER FUNCTIONS EXPLAINED
INITIAL SETUP AND RESET
Begin by resetting the
Art.380N/UK
to the factory defaults using the programming command:
** 371 33 1111.
IMPORTANT NOTE: If you are unable to reset using this process because an access code has been enabled but you are not sure
what it is then follow the manual reset procedure:
1. Switch
OFF
the mains power to the
Art.380N/UK
;
2. Short out the terminals
-
and
SK
, see
Fig.17
;
3. Switch
ON
the mains power to the
Art.380N/UK
;
4. Remove the short between terminals
-
and
SK
, see
Fig.18
;
5. The
Art.380N/UK
has now been reset to the factory
default settings.
This method will also switch the
Art.380N/UK
into
PABX
mode
so unless this mode is required in order to revert the unit back
to normal mode, pickup the handset and type
** 371 14 0
and
listen for the line tone to change to the normal dial tone.
Fig. 17
Fig. 18
Programming the Art.380N/UK