PROJECT INFORMATION
APPROVAL STAMP
Project:
q
Approved
Address:
q
Approved as noted
Contractor:
q
Not approved
Engineer:
Remarks:
Submittal Date:
Notes 1:
Notes 2:
NOTICE
: Ductile iron fittings have higher tensile strength than that of steel pipe.
Therefore, over tightening can cause damage to pipe threads which may cause
leakage. Ductile iron fittings should be tightened approximately three turns beyond
hand tight, but no more than four turns.
SPF/DI-1.15
DUCTILE IRON THREADED FITTINGS
Dimensions: ASME B16.3
Material: ASTM A536 Grade 65-45-12
Finish:
Black
Threads: NPT per ASME B1.20.1
Agency Approvals: All ductile iron threaded fittings are
UL/ULC Listed and FM Approved.
MATERIAL SPECIFICATIONS
FIG. 3205R
Reducing Tee
For Listings/Approval Details and Limitations,
visit our website at www.anvilintl.com or
contact an Anvil
®
Sales Representative.
FIGURE 3205R - REDUCING TEE
Nominal Size
Max.
Working
Pressure
s
Dimensions
Approx.
Wt. Each
1 x 2 x 3
A
B
C
In. (mm)
PSI (kPa)
In. (mm)
In. (mm)
In. (mm)
Lbs. (kg)
1 x
1
⁄
2
x 1
500
1.50
1.36
1.50
0.64
25 x 15 x 25
3450
38.10
34.54
38.10
0.29
1 x
3
⁄
4
x 1
500
1.50
1.45
1.50
0.73
25 x 20 x 25
3450
38.10
36.83
38.10
0.33
1 x 1 x
1
⁄
2
500
1.26
1.26
1.36
0.71
25 x 25 x 15
3450
32.00
32.00
34.54
0.32
1 x 1 x
3
⁄
4
500
1.37
1.37
1.45
0.76
25 x 25 x 20
3450
34.80
34.80
36.83
0.34
1 x 1 x 1
1
⁄
4
*
500
1.67
1.67
1.58
0.98
25 x 25 x 32
3450
42.41
42.41
40.13
0.44
1 x 1 x 1
1
⁄
2
*
500
1.80
1.80
1.65
1.16
25 x 25 x 40
3450
45.72
45.72
41.91
0.53
1
1
⁄
4
x 1 x
1
⁄
2
*
500
1.34
1.26
1.53
0.82
32 x 25 x 15
3450
34.04
32.00
38.86
0.37
1
1
⁄
4
x 1 x
3
⁄
4
500
1.45
1.37
1.62
0.90
32 x 25 x 20
3450
36.83
34.80
41.15
0.41
1
1
⁄
4
x 1 x 1
500
1.58
1.50
1.67
1.00
32 x 25 x 25
3450
40.13
38.10
42.42
0.45
1
1
⁄
4
x 1 x 1
1
⁄
4
500
1.75
1.67
1.75
1.08
32 x 25 x 32
3450
44.45
42.42
44.45
0.49
1
1
⁄
4
x 1 x 1
1
⁄
2
500
1.88
1.80
1.82
1.42
32 x 25 x 40
3450
47.75
45.72
46.22
0.64
1
1
⁄
4
x 1
1
⁄
4
x
1
⁄
2
500
1.34
1.34
1.53
0.86
32 x 32 x 15
3450
34.04
34.04
38.86
0.39
FIGURE 3205R - REDUCING TEE
Nominal Size
Max.
Working
Pressure
s
Dimensions
Approx.
Wt. Each
1 x 2 x 3
A
B
C
In. (mm)
PSI (kPa)
In. (mm)
In. (mm)
In. (mm)
Lbs. (kg)
1
1
⁄
4
x 1
1
⁄
4
x
3
⁄
4
500
1.45
1.45
1.62
0.92
32 x 32 x 20
3450
36.83
36.83
41.15
0.42
1
1
⁄
4
x 1
1
⁄
4
x 1
500
1.58
1.58
1.67
0.95
32 x 32 x 25
3450
40.13
40.13
42.42
0.43
1
1
⁄
4
x 1
1
⁄
4
x 1
1
⁄
2
*
500
1.88
1.88
1.82
1.45
32 x 32 x 40
3450
47.75
47.75
46.22
0.66
C
A
B
3
1
1 x 2 x 3
2
s
Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact
your local Anvil Representative.
*
Part supplied as "Bull Head Tee".
Summary of Contents for VicFlex AH1
Page 26: ......
Page 27: ......
Page 44: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...
Page 75: ......
Page 76: ......
Page 93: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...
Page 124: ......
Page 125: ......
Page 142: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...
Page 153: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...
Page 184: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...
Page 215: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...