FP-4.12
PROJECT INFORMATION
APPROVAL STAMP
Project:
q
Approved
Address:
q
Approved as noted
Contractor:
q
Not approved
Engineer:
Remarks:
Submittal Date:
Notes 1:
Notes 2:
The Model RC-2 Reducing Coupling makes it possible to
directly connect two different pipe sizes, eliminating the need
for two couplings and a reducing fitting. The specially designed
reducing coupling gasket with a center rib assures proper
positioning of the gasket and prevents the smaller pipe from
telescoping into the larger during assembly.
Working pressure ratings shown are for reference only and are
based on schedule 40 pipe. For the latest UL/ULC listed, LPCB,
VdS and FM Approved pressure ratings versus pipe schedule,
see www.anvilintl.com or contact your local Anvil Representative.
Model RC-2 Coupling complete with Grade “E” EPDM Gasket.
MATERIAL SPECIFICATIONS
HOUSING:
Ductile Iron conforming to ASTM A-536, Grade 65-45-12
ANSI BOLTS & HEAVY HEX NUTS:
Heat treated, oval-neck track head bolts conforming to the physical properties of
SAE J429 Grade 5 with a minimum tensile strength of 120,000 psi and heavy
hex nuts of carbon steel conforming to ASTM A-563 Grade A, or J995 Grade 2.
Bolts and nuts are provided zinc electroplated as standard.
METRIC BOLTS & HEAVY HEX NUTS:
Heat treated, zinc electroplated oval-neck track head bolts made of carbon
steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and
bolts are zinc electroplated followed by a yellow chromate dip.
COATINGS:
q
Rust inhibiting paint Color: ORANGE (standard)
q
Hot Dipped Zinc Galvanized (optional)
q
Other available options: Example: RAL3000 or RAL9000 Series
For other coating requirements contact an Anvil Representative.
LUBRICATION:
q
Standard Gruvlok
q
Gruvlok Xtreme™ required for freezer applications.
GASKETS:
Materials
Properties as designated in accordance with ASTM D-2000.
q
Grade “E” EPDM
(Green color code)
-40°F to 230°F (Service Temperature Range)(-40°C to 110°C)
Recommended for water service, diluted acids, alkalies solutions,
oil-free air and many chemical services.
NOT FOR USE IN PETROLEUM APPLICATIONS.
FIG. RC-2
Reducing Coupling
For Listings/Approval Details and Limitations, visit our website at
www.anvilintl.com or contact an Anvil
®
Sales Representative.
VdS
Summary of Contents for VicFlex AH1
Page 26: ......
Page 27: ......
Page 44: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...
Page 75: ......
Page 76: ......
Page 93: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...
Page 124: ......
Page 125: ......
Page 142: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...
Page 153: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...
Page 184: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...
Page 215: ...PDF Created with deskPDF PDF Writer Trial http www docudesk com...