Function Parameter Table VD500 Series Inverter User Manual
- 46 -
F1-11
Stop DC Braking
Current
0%~100%
0%
○
F1-12
Stop DC Braking
Time
0.0s~100.0s
0.0s
○
F1-13
Stop Frequency
0.00Hz~max frequency
0.50
○
F1-14
Stop Frequency
Holding Time
0.0s~60.0s
0.0s
○
F1-15
Restart Selection
Upon Power
Failure
0: Enabled
1: Disabled
0
○
F1-16
Waiting Time of
Restart Upon
Power Failure
0.0s~60.0s
0.0s
○
F1-17
Operation Mode of
Set Frequency is
Lower than the
Frequency Lower
Limit
0: Running with frequency lower limit
1: Stop
2: Zero speed running
0
○
F1-18
Start Selection of
Set Frequency is
Lower than the
Start Frequency
0: Don’t start
1: Zero speed running
1
◎
F1-19
Run Direction
0: Same direction
1: Opposite direction
0
○
F1-20
Reverse Control
Enable
0: Allow reverse
1: Prohibit reverse
0
○
F1-21
FWD/REV
Rotation
Dead-zone Time
0.0s~3000.0s
0.0s
○
F1-22
Dynamic Braking
Enable
0: Disabled
1: Enabled
0
○
F1-23
Braking Usage
Rate
0%~100%
100%
○
F1-24
Over-excitation
Effective Range
0: The whole is effective
1: Only overpressure stall enable
effectively
2: Only deceleration process
effectively
3: The whole is invalid
1
◎
F1-25
Over-excitation
Gain
0~200
100
○
F1-26
Over-excitation
Filter Coefficients
0~10
3
○