Parameter Description VD500 Series Inverter User Manual
- 130 -
Setup frequency
or torque
Setup frequency
or torque
100%
100%
AI
AI
0V/0mA
0V/0mA
-100%
10V/20mA
10V/20mA
Fig 6-15 Corresponding relationship between analog reference and setting
F5-27
AI Curve 2 Min Input
-10.00V~F5-29
0.00V
○
F5-28
Corresponding Setting of
AI Curve 2 Min Input
-100.0%~+100.0%
0.0%
○
F5-29
AI Curve 2 Max Input
F5-27~+10.00V
10.00V
○
F5-30
Corresponding Setting of
AI Curve 2 Max Input
-100.0%~+100.0%
100.0%
○
F5-31
AI 2 Filter Time
0.00s~10.00s
0.10s
○
The function and using method of curve 2, please refer to the insctructions of curve 1.
F5-32
AI Curve 3 Min Input
-10.00V~F5-34
0.00V
○
F5-33
Corresponding Setting of
AI Curve 3 Min Input
-100.0%~+100.0%
0.0%
○
F5-34
AI Curve 3 Max Input
F5-32~+10.00V
10.00V
○
F5-35
Corresponding Setting of
AI Curve 3 Max Input
-100.0%~+100.0%
100.0%
○
The function and using method of curve 3, please refer to the instructions of curve 1.
F5-37
Pulse Min Input
0.00kHz~F5-39
0.00kH
z
○
F5-38
Corresponding Setting of
Pulse Min Input
-100.0%~+100.0%
0.0%
○
F5-39
Pulse Max Input
F5-37~100.00kHz
50.00k
Hz
○
F5-40
Corresponding Setting of
Pulse Max Input
-100.0%~+100.0%
100.0%
○
F5-41
PULSE Filter Time
0.00s~10.00s
0.10s
○