Function Parameter Table VD500 Series Inverter User Manual
- 88 -
b0-29
User Code 29
FF-06
○
b0-30
User Code 30
FF-06
○
b0-31
User Code 31
FF-06
○
b1 Virtual IO
Function
Code
Parameter Name
Setting Range
Factory
Default
Value
Property
b1-00
Virtual VDI1
Terminal Function
Selection
0~59
0
◎
b1-01
Virtual VDI2
Terminal Function
Selection
0~59
0
◎
b1-02
Virtual VDI3
Terminal Function
Selection
0~59
0
◎
b1-03
Virtual VDI4
Terminal Function
Selection
0~59
0
◎
b1-04
Virtual VDI5
Terminal Function
Selection
0~59
0
◎
b1-05
Virtual VDI
Terminal State
Setting Mode
Unit’s digit: virtual VDI1
0: By virtual VDOx state to decide VDI
is valid or not
1: By code b1-06 setting VDI is valid
or not
Ten’s digit: virtual VDI2, same as
above
Hundred’s digit: virtual VDI3, same as
above
Thousand’s digit: virtual VDI4, same
as above
Ten thousand’s digit: virtual VDI5,
same as above
0x00000
◎
b1-06
Virtual VDI
Terminal state
setting
Unit’s digit: virtual VDI1
0: Disabled
1: Enabled
Ten’s digit: virtual VDI2, same as
above
Hundred’s digit: virtual VDI3, same as
above
Thousand’s digit: virtual VDI4, same
as above
Ten thousand’s digit: virtual VDI5,
0x00000
◎