70
V2002D-PTZ
User’s Manual
Performance
Switch to the Live View page and select “Intrusion” from the lower
-left VA dropdown menu. When
there is a moving object trespassing into the designated critical zone defined by administrator, as in
the above image, both the rectangular frame enclosing the suspicious object and the defined zone
are highlighted with red color for distinctive identification. Additionally, any moving object within the
Live view will be framed by a blue rectangle for clear recognition.
8.10
Object Removed
Object Removed detection was developed with the objective to guarantee that selected valuable
objects are properly monitored and safeguarded. For example, the owner of a jewelry store would
want to secure that each piece of jewelry is protected.
Figure: Object Removed Settings
Basic Setting
Trigger Interval
Define an exact threshold of time to trigger Object Removed detection. Either use the slider or enter an
exact number in the field.
Zone 1 ~ 3
Check the box to enable each zone setting. Press the arrow buttons at the upper-right corner to
expand or collapse the setting page of Zone 1 to Zone 3 individually.
Method
Draw a desired rectangular zone covering the critical item for Object Removed detection and then
click
“Save” to have the settings take effect
. Up to 3 zones can be set up having varied color
indications.