35
•
HMI service unit for Saphir regulator operation
(ACX84.910/ALG) – only by request
Equithermal control without space effect
•
Outside sensor QAC34/101
•
Thermostatic valve (Filling valve) - series VTC312
(external thread) from ESBE (minimum return water
temperature 45
o
C) (ord. code: 5100 15 00)
•
Three-way valve V4044C (only in case boiler is used
for HW heating)
•
Warm water sensor QAZ36 (only in case boiler is
used for HW heating)
Mixing heating circuit – configuration
Boiler equipment
Type of operation
Necessary boiler accessories
•
QAA 88 device – space unit
Equithermal control with space effect
•
Outside sensor QAC34/101
•
Thermostatic valve (Filling valve) - series VTC312
(external thread) from ESBE (minimum return water
temperature 45
o
C) (ord. code: 5100 15 00)
•
Three-way mixing valve VBI31.20 with drive
SQK34.00
•
Heating branch sensor QAD36/101
•
Water heater thermostat type: 7K1.6R326.00A (only
in case boiler is used for HW heating.)
•
QAA 88 device – boiler unit
Equithermal control without space effect
•
Outside sensor QAC34/101
•
Thermostatic valve (Filling valve) - series VTC312
(external thread) from ESBE (minimum return water
temperature 45
o
C) (ord. code: 5100 15 00)
•
Three-way mixing valve VBI31.20 with drive
SQK34.00
•
Heating branch sensor QAD36/101
•
Water heater thermostat type: 7K1.6R326.00A (only
in case boiler is used for HW heating)
•
QAA 88 device – space unit
Space control
•
Outside sensor QAC34/101 – is not used
•
Thermostatic valve (Filling valve) - series VTC312
(external thread) from ESBE (minimum return water
temperature 45
o
C) (ord. code: 5100 15 00)
•
Three-way mixing valve VBI31.20 with drive
SQK34.00
•
Heating branch sensor QAD36/101
•
Water heater thermostat type: 7K1.6R326.00A (only
in case boiler is used for HW heating.)
•
QAA 88 device – space unit
Equithermal control with space effect
•
HMI service unit for Saphir regulator operation
(ACX84.910/ALG) – only by request
•
Outside sensorQAC34/101
•
Thermostatic valve (Filling valve) - series VTC312
(external thread) from ESBE (minimum return water
temperature 45
o
C) (ord. code: 5100 15 00)
•
Three-way mixing valve VBI31.20 with drive
SQK34.00
•
Heating branch sensor QAD36/101
•
Water heater thermostat type: 7K1.6R326.00A (only
in case boiler is used for HW heating)