3
Dear customer,
we thank you that you have bought EKORET SAPHIR automatic solid fuel boiler and thus having
shown your confidence in VIADRUS a.s.
For you to get used to a correct way of handling your new product from the beginning, please read at
first this manual for usage (mainly chapter no. 6 – Boiler operation by user and chapter no.
7 – Important cautions). Please follow the bellow stated information at once – and respect the
producer´s, eventually assembly company´s which installed the boiler, instructions to be provided a
longterm failure-free boiler operation to your satisfaction.
1.
Boiler usage and advantages
The hot-water automatic boiler EKORET SAPHIR for solid fuel is designated first of all for heating the
houses, weekend houses, small premises, ect.
Boiler advantages:
•
Boiler automatic operation controlled by an indoor device providing a convenience
•
HWS (hot service water) preparation possibility
•
Mechanical fuel supply from the built-in reservoir
•
Simple, time saving operation and maintenance
•
Low operating costs
•
Low emissions
•
High efficiency
2.
Boiler technical data
Tab. no. 1 Boiler dimensions, technical parameters
EKORET SAPHIR 15
3 sect.
EKORET SAPHIR 25
4 sect.
Boiler weight including small reservoir
kg
359
385
Boiler weight including large reservoir
kg
392
418
Water space volume
l
34,1
45,5
Diameter of smoke socket
mm
150
150
Fuel reservoir capacity – small
dm
3
269
269
Fuel reservoir capacity – large
dm
3
528
528
Boiler dimensions
(including small fuel reser.):
width x depth x height
mm
1218 x 693 x 1592
1218 x 693 x 1592
Boiler dimensions (including large reser.):
width x depth x height
mm
1867 x 693 x 1592
1867 x 693 x 1592
Filling hole dimensions – small reservoir
mm
422 x 545
422 x 545
Filling hole dimensions – large reservoir
mm
422 x 1210
422 x 1210
Working water overpressure
kPa (bar)
250 (2,5)
250 (2,5)
Testing water overpressure
kPa (bar)
500 (5)
500 (5)
Recommended operating temperature of
heating water
°C
50 - 85
50 - 85
Minimum return water temperature
°C
45
45
Hydraulic resistance collector
2,015
2,015
Noise level
dB
Doesn´t exceed level 65 dB (A)
Chimney draught
mbar
0,10 – 0,20
0,10 – 0,20
Boiler connections – heating water
Js
G 1 1/2”
G 1 1/2”
– return water
Js
G 1 1/2”
G 1 1/2”
Connecting voltage
1/N/PE 230V AC 50 Hz TN - S
Electric input
W
100
Electric coverage
IP 40