10
Fuel positioning:
•
For the right burning in the boiler it is necessary to use the dry fuel. The producer recommends to
store the fuel in the cellar area or at least under the shelter.
•
It is interdicted to store the fuel behind the boiler or next to the boiler within a distance smaller than
400 mm,
•
The producer recommends to keep the distance between the boiler and fuel min. 1 000 mm, or to store
the fuel in a different room that where the boiler is installed.
It must be ensured the continuous air supply into the room, where the boiler is installed for burning and
eventual ventilation (the air consumption of EKORET SAPHIR boiler makes for 15 kw boiler 45 m
3
. h
-1
, and
for 25 kW boiler 75 m
3
. h
-1
). The heating system pipe connection, eventually the heater heating insert
connection, must be done by the authorized person.
CAUTION: When connecting the boiler to the heating system there must be installed a drain tap in the
lowest point and as near as possible to the boiler.
Fig. no. 5
Boiler (the right version with a small reservoir) with the open fuel reservoir