Manual for:
VGE Pro UV Control 400/420/600 and VGE Pro UV Control 140/200
EP600001, EP200002
status indication
(see 'Status indication' on page 10 for details)
operating status indicated
- via LCD front end:
– by 4 line alphanumeric LCD: 4*20 digits
– by LCD backlight colour: green, yellow and red
- via base unit:
• by 4 potential free relays ('system OK', 'alarm', 'warning')
• by status LEDs for lamp operationoperation modes
– manual start/stop via LCD front end
– automatic start/stop via mains switch (refer to menu settings)
– remote start/stop via remote input (refer to menu settings)
Connections
refer to chapter Wiring at page 8 for wiring scheme
mains terminal
X1
1. PE
2. PE
3. L
4. N
main switch terminal
X2
1./4. contacts for switching N
2./3. contacts for switching L
lamp terminals
X3/X4/X5
for supply voltage 230V AC ±10%, 45...65Hz
• section ratings:
◦ control section: 90...253V AC, 45...65Hz
◦ interlock section: min. 170V AC
◦ ballast section (powered via mains relay): voltage control 207...253V AC
• brownout detection, automatic lamp restart when
appropriate for connection of a bipolar power switch
appropriate contacts have to be closed to power the system
• rating: 250V AC / 16A
see above for lamp specification
relay terminals 1/2/3/4 signaling relays according to system states,
X6
1./4./7./10. normally closed
2./5./8./11. change over
3./6./9./12. active contact
'digisens'
digital sensor terminal
X7
1. 12V DC supply
2. signal A (+)
3. signal B (-)
4. ground for supply
'UV' UV diode
sensor terminal
X8
1. cathode
2. anode+shield
'I
in
'
current input terminal
X9
1. 12V DC supply
2. signal
3. ground for supply
relay function depends on operating software
potential free, resistive load:
• max. current 8A at 250V AC, 24V DC
• min. current 10mA at 5V
• max. voltage: 250C AC, 80V DC
Note:
When switching inductive loads, connect a surge protector in parallel with the load.
interface for digital sensors (UV and temperature) including 12V DC supply
• galvanically isolated
• 12V DC supply voltage:
◦ not sustained short circuit proof (short circuit current: max. 250mA, max. 10s)
Note:
The sensor cable shield must be open on the sensor plug connector.
Note:
The overall power consumption of 'switch 2', 'digisens' and 'current input I
in
' must not
exceed 1.5W, otherwhile the unit will be switched off automatically.
interface for UV diode sensors
• types with isolated diode element required
• cable length: max. 2.90m
• connect sensor shield to terminal 'A',
Note:
The sensor cable shield must be open on the sensor plug connector,
the sensor shield must not be connected externally to ground potential.
4...20mA signal input including 12V DC supply for external module
• internal resistance: 25Ω
• 12V DC supply voltage:
◦ output power: max. 1W
◦ short circuit proof
(supply voltage and base unit will be shut off in case of short circuit)
Note:
The overall power consumption of 'switch 2', 'digisens' and 'current input I
in
' must not
exceed 1.5W, otherwhile the unit will be switched off automatically.