Manual for:
VGE Pro UV Control 400/420/600 and VGE Pro UV Control 140/200
EP600001, EP200002
'I
out
'
current output
X10
1. signal
2. signal ground
'temp'
temperature sensor
terminal
X11
1. KTY (-) sensor signal
2. KTY (+) sensor signal
3. cable shield
'modbus'
RS485 terminal
X12
1. signal A (+)
2. signal B (-)
3. ground
'switch 2'
switching input 2
terminal
X13
1. contact A / 12V DC supply
2. contact B
3. ground for supply
'frontend'
control panel terminal
X14
RJ45 western plug
'switch 1'
switching input 1
terminal
X15
1. contact A
2. contact B
'interlock 1'
X18
1. contact A
2. contact B
4...20mA output signal corresponding to UV value
• active signal output, galvanically isolated
• output voltage: max. 15V DC
• max. load: 450Ω
interface for analog temperature sensor
• types: KTY110, KTY210 (type selection via menu)
• including ground connection for sensor cable shield
Note:
The sensor cable shield must be open on the sensor plug connector,
the sensor shield must not be connected externally to ground potential.
RS485 interface to superiour control unit
• galvanically isolated
• including ground connection for cable shield
• no internal termination or biasing
switching input including 12V DC supply for external module
function depends on operating software
• holding current: 1mA at loop resistance 0Ω
• loop resistance: max. 1kΩ
• 12V DC supply voltage:
◦ output power: max. 1W
◦ not sustained short circuit proof
(short circuit current: max 250mA, max. 10s)
Note:
The overall power consumption of 'switch 2', 'digisens' and 'current input I
in
' must not
exceed 1.5W, otherwhile the unit will be switched off automatically.
interface to control panel
• connection using CAT5e patch cable
• includes power supply and data connection
Note:
No Ethernet function implemented. Do not connect to any Ethernet periphery.
switching input 100...250V AC for remote start/stop
100...250V AC have to be applied to contacts A+B for remote start,
if remote function is enabled via menu
• power-on threshold: min. 100V AC
• switch-on/off hysteresis: typ. 15V AC
• internal resistance: 180kΩ
hardware-interlock (affects the power supply of the mains relay)
closing contacts A+B enables ballast function and powers ballast section
• supply by base unit
• holding current: 5...15mA DC
• open-loop voltage: max. 30V DC
• max. cablelength per interlock-loop: 29.9m;
for cablelength larger then 2.90m use a ferrite cable core type WÜRTH 74270053 near
the terminal ends, wind both cable ends 1x through the cable core.
Safety note:
The mains relay operation is additionally controlled by a safety circuit. If the mains
relay deactivation fails (e.g. caused by sticking contacts) lamps are switched off and the ballast
function is deactivated and locked.
Warning:
The ballast section remains on mains potential in
this case.