VGEM000-GB192
Pag. 50/68
VGE International B.V.
●
Ekkersrijt 4304
●
5692 DH Son Netherlands
●
+31 499 461099
●
●
www.vgebv.nl
Installation & User Manual
8 Maintenance
The correct functioning of a VGE Pro UV system is only guaranteed if original spare parts and components
are used as described in this manual. The parts described must also be inspected, replaced or cleaned in a
timely manner. If instructions are not followed, there is a risk of malfunction or damage to the UV system. If
non-original spare parts and components are used or if the inspection, replacement or cleaning is not
carried out in time, the warranty on the entire UV system will lapse.
The safety instructions in this manual must be followed at all times, but they do not
affect the local and/or legally applicable safety measures and instructions.
UV-C radiation can damage the retina of your eyes and unprotected skin. Ensure
that you are not directly or indirectly exposed to UV radiation.
Everyone involved must be informed about the specific hazards associated with a
VGE Pro UV system.
Installation, maintenance and service work must be carried out by VGE International
B.V. trained and authorized persons.
Grasp all quartz glass parts only with clean gloves on, which do not leave any
residues or prints (included). If fingerprints or dirt are present on the quartz parts,
the UV-C radiation is negatively influenced, so that the UV-C treatment process is
also negatively affected.
Quartz can cause serious cuts in the event of breakage.
General steps of maintenance:
1. Switch off the UV system and lock the main switch;
2. Shut off the hydraulic supply and discharge for the UV system;
3. Drain the water from the unit;
4. Perform the specific maintenance as described in this chapter;
5. Remove the lock on the main switch and switch on the UV system in accordance with the conditions
described in the chapter 'Water in the system';
6. Check whether the UV lamp is burning.
All adjustments, actions and controls must be documented in the logbook.