VGEM000-GB192
Pag. 22/68
VGE International B.V.
●
Ekkersrijt 4304
●
5692 DH Son Netherlands
●
+31 499 461099
●
●
www.vgebv.nl
Installation & User Manual
2.10 Operating conditions
The VGE Pro INOX MP series UV systems can operate at an ambient temperature
b5 °C and +40 °C and at a relative humidity of 10% to 95% (non-
condensing).
Before switching on the UV lamps, the irradiation chamber must be completely filled
and flowed through with sufficient water. This is to prevent dangerous situations for
the UV system, the environment and users.
The water that flows through the UV system may have a temperature between
+1 °C and +60 °C. A bimetallic switch is mounted on the irradiation chamber as
protection, which switches off the UV lamp at a maximum irradiation chamber
temperature of +60 °C. The irradiation chamber can operate with a maximum
operating pressure of the water of 10 bar. Water hammer can irreversibly damage
the irradiation chamber or parts thereof.
The control panel and the irradiation chamber must not be mounted in direct sunlight
and must be protected against rain and other moist precipitation. The environment
must be free of chemical vapours, (liquids) substances and/or radiation that can
damage the UV system. The control panel and irradiation chamber must also be
mounted vibration-free.