VGEM000-GB192
Pag. 24/68
VGE International B.V.
●
Ekkersrijt 4304
●
5692 DH Son Netherlands
●
+31 499 461099
●
●
www.vgebv.nl
Installation & User Manual
The UV systems are supplied with the UV lamps packed separately.
If a UV system has to be moved to another location after installation, the following must be taken into
account:
-
Remove the UV lamps from the irradiation chamber and package them in their original packaging;
-
Ensure that the cables connected to the UV system are completely disconnected;
-
Pack the UV system in such a way that it cannot be damaged or contaminated during transport;
-
If necessary, use properly maintained and approved lifting material to prevent damage to the
irradiation chamber and/or control panel;
-
Cables may not be used to lift or move the irradiation chamber and/or the control panel.
Upon receipt of the UV system, check whether the delivery is complete based on the waybill.
3.3 Storage
If possible, only unpack the product shortly before assembly.
Protect the product during storage against:
-
Rain and moisture;
-
Dust and dirt;
-
Shocks and vibrations;
-
Radiation (electromagnetic, electrostatic and ionizing);
-
Temperatures outside the range of +1 °C to +60 °C.
If a UV system is (temporarily) taken out of operation, we recommend rinsing the irradiation chamber with
clean water to remove sand, salt and other corrosive substances to prevent corrosion. Ensure that the
irradiation chamber is dry and clean to prevent contamination, microbiological contamination and corrosion.
If a UV system is (temporarily) taken out of operation and dismantled, we recommend that the individual
components are stored in their original packaging and that the above storage instructions are observed.
Make sure the irradiation chamber is dry and clean to prevent contamination, microbiological contamination
and corrosion.
3.4 Warranty
The warranty period for our VGE Pro UV systems is twelve (12) months from the moment of acceptance
(acceptance is the first use of the relevant UV system or a validated acceptance/start-up protocol). The
moment of acceptance must be within three (3) months after shipment of the relevant product. If the
acceptance is not realized within three (3) months after shipment, the warranty period starts on the date
three (3) months after the shipment date. Consumables (for example: UV lamps, quartz tubes, O-rings, etc.)
of the VGE Pro UV systems are excluded from this warranty. A prerequisite for this guarantee period is
error-free installation and start-up, fully documented periodic inspection and maintenance on a minimum of
half a year and the operating instructions must be followed.