VGEM000-GB192
VGE International B.V.
●
Ekkersrijt 4304
●
5692 DH Son Netherlands
●
+31 499 461099
●
●
www.vgebv.nl
Pag. 53/68
Installation & User Manual
The mounting flange can be fixed by means of the included M5x10
bolts (7).
Use only the original screws. These are provided with a special coating to prevent
high friction from stainless steel to stainless steel. The coating prevents the screws
from blocking. Use a screwdriver with an adjustable torque (Nm) at all times. Also
called torque screwdriver/key. Loosely screw in the screws by hand. Tighten the
screws using the torque screwdriver crosswise, with a maximum force of 0.8 Nm
(see drawing 27).
Do not screw in the screws by machine! It must be easy to screw in the
screws.
Check again if the gasket (10) is locked in by
the quartz tube (11) and aluminium sleeve (9).
Check the quartz tube again for damage.
Drawing 26
Drawing 27
Drawing 4