66
PktBlaster SDN Controller Test-Performance Benchmarking User Guide
Copyright © Veryx Technologies Pvt. Ltd
.
3.
To configure the latency test normal mode parameters, go to the
Test
Configuration
pane.
Figure 47: Test Configuration-Latency Normal Mode
4.
Under
Test Type
, select
Latency
.
5.
From the
Test Mode
drop-down list, select
Normal
.
6.
In
Flow Measured By
, select the type of response the controller should send
to the simulated switches.
7.
In the
Duration (sec)
box, type or select the test duration. Here, the test
duration is set to 5 seconds.
8.
In the
# of Iterations
box, type or select the number of times the test has to
be repeated. Here, the number of iterations is set to four.
9.
In the
Iteration Delay (sec)
box
,
specify the number of seconds the test
should pause before it starts the next iteration to flush out the requests
received during the previous iteration.
10.
In
Warmup Time (sec)
, specify the number of seconds the test should wait
after the handshake with the controller is completed.