Executing Throughput Tests
Throughput Test in Incremental Switch Mode
In this mode of throughput testing, OpenFlow packet-in messages are first sent to
the controller from 25% of the configured number of switches belonging to a single
switch group network. This test is repeated in increments of 25% until all the
configured switches have sent packet-in messages to the controller. This would
require 4 iterations. It is not possible to change the number of iterations in the test.
To run a throughput test in the Incremental Switch mode:
1.
Click the
Performance
tab to display the
Performance
screen (Figure 25).
2.
Configure the
Select Controller
pane and
Network Configuration
pane
(Figure 27).
For details of how to configure the panes, refer to
Configure Test Parameters
section in the
Performance Tests
chapter.
To continue configuring the test parameters, go to the
Test Configuration
pane.
Figure 42: Test Configuration- Throughput Incremental Switch Mode