2-4.2.2.2 Static Table
The section describes how to configure the Static IP Source Guard Table parameters of the
switch. You could use the Static IP Source Guard Table configuration to manage the entries.
Web Interface
To configure a Static IP Source Guard Table Configuration in the web interface:
1.
Click “Add new entry”.
2.
Specify the Port, VLAN ID, IP Address, and MAC address in the entry.
3.
Click Apply.
Figure 2-4.2.2.2: The Static IP Source Guard Table
Parameter description:
Delete
Check to delete the entry. It will be deleted during the next save.
Port
The logical port for the settings.
IP Address
Allowed Source IP address.
MAC address
Allowed Source MAC address.
Adding new entry
Click to add a new entry to the Static IP Source Guard table. Specify the Port, VLAN ID, IP
address, and IP Mask for the new entry. Click "Save".
Buttons
Apply – Click to save changes.