Unit will not run in the
compressor relay test
mode. **NOTE: Leave
the compressor relay
test mode on, in order to
check for voltage.
Defective control board.
Unplug unit at power distibution panel. Remove
air dam. Reconnect power. Enable compressor
relay through Test Mode. Check 2-pin connection
on power distribution for 110V.
Defective relay.
Upon opening the cabinet door, the lights and
fans should shut off. If they don’t, replace the
cabinet switch.
Refrigeration unit runs
constantly.
Defective cabinet switch.
Upon opening the door, the display should read
either errors, summary sales, or none. If it does
not, then replace the cabinet switch.
Defective control board.
Replace control board.
Defective relay - contacts are
welded together.
Replace relay.
Compressor will not start. Overload protector inoperative.
Check overload (apply insulated jumper across
terminal, if compressor starts, replace overload).
Defective cabinet switch.
Check for error codes. Replace cabinet switch.
Compressor will not start,
condenser fan motor
running - unit hot (power
to compressor).
Defective over load relay
Replace the over load relay.
Compressor motor rocked
Replace the refer unit.
Defective capacitor
Replace the capacitor.
Defective PTC relay
Replace the PTC relay.
Compressor starts but
does not run.
Loss of refrigerant
Replace the refrigeration unit.
Smashed tubings and capillary
Replace the refrigeration unit.
Defective over load relay
Replace the over load relay.
Compressor runs but
cabinet temperature
warm.
Loss of refrigerant
Replace the refrigeration unit.
Smashed tubings
Replace the refrigeration unit.
Defective drainage
Make sure the drain hose is not kinked or
clogged.
Defective temperature sensor
Replace the temperature sensor.
Poor air flow
Make sure nothing is sitting in front of the
evaporator.
Defective control board
Replace the control board.
Defective door seal
Make sure the vend flap and gasket are not open.
Defective heat exchange on
condenser/ Blocking air flow by
dust, lint or fins damage
Clean the surface of the condenser fins or
straighten the bent fins.
Both compressor and
condenser fan motors will
not operate.
Bad refrigeration control relay.
Test relay using relay test function of the
electronic controller. Replace relay if necessary.
Bad connection at power board.
Check wiring connections. Make corrections if
necessary.
Evaporator frosted over.
Loss of refrigerant
Replace the refrigeration unit.
Smashed tubings
Replace the refer unit.
Defective drainage
Make sure the drain hose is not kinked or
clogged. Re-install hose correctly if kinked or
clogged.
Defective temperature sensor
Replace the temperature sensor.
Defective control board
Replace the board.
Poor sealing
Check gasket, vend flap, and permagum on the
bulkhead.
Summary of Contents for VARI-PAK 450
Page 2: ...TC 1 07 2003 PARTS AND SERVICE MANUAL VARI PAK...
Page 5: ...S 1 07 2003 SAFETY SECTION VARI PAK...
Page 8: ...S 4 07 2003 FIGURE 1...
Page 20: ...S 16 07 2003 NOTES...
Page 21: ...G 1 07 2003 GENERAL INFORMATION SECTION VARI PAK...
Page 28: ...G 8 07 2003 NOTES...
Page 29: ...CL 1 07 2003 CLEANING INFORMATION SECTION VARI PAK...
Page 32: ...CL 4 07 2003 NOTES...
Page 33: ...PG 1 07 2003 14 1 PROGRAMMING SECTION VARI PAK...
Page 57: ...C 1 07 2003 CABINET PARTS SECTION VARI PAK...
Page 59: ...C 3 07 2003 HARDWARE LIST...
Page 60: ...C 4 07 2003...
Page 61: ...C 5 07 2003...
Page 62: ...C 6 07 2003...
Page 64: ...C 8 07 2003...
Page 66: ...C 10 07 2003...
Page 68: ...C 12 07 2003...
Page 70: ...C 14 07 2003...
Page 72: ...C 16 07 2003...
Page 75: ...C 19 07 2003 NOTES...
Page 76: ...D 1 07 2003 DOOR PARTS SECTION VARI PAK...
Page 77: ...D 2 07 2003...
Page 79: ...D 4 07 2003...
Page 81: ...D 6 07 2003...
Page 83: ...D 8 07 2003...
Page 85: ...D 10 07 2003...
Page 87: ...D 12 07 2003...
Page 89: ...D 14 07 2003...
Page 91: ...D 16 07 2003 NOTES...
Page 92: ...M 1 07 2003 MAINTENANCE SECTION VARI PAK...
Page 98: ...M 7 07 2003 FIGURE 2...
Page 100: ...M 9 07 2003 NOTES...
Page 101: ...T 1 07 2003 TROUBLESHOOTING SECTION VARI PAK...
Page 112: ...T 12 07 2003 NOTES...