Bill Validator Open
Bill validator is open.
Check that bill cashbox is closed
and in correct position.
If cashbox appears to be OK,
replace bill acceptor.
Bill Validator Sensor Bill validator sensor is
not functioning.
Check bill validator for
obstructions or dirt.
If no obstructions are
apparent, replace bill validator.
Card Reader
Card Reader
Communication
There is no card reader
communication for 5
seconds.
If card reader/bill acceptor is
being used, check for “rC’ or
“bC” errors.
If there is no “rC” or “bC” error:
1) Check changer harness.
2) Replace changer.
Turn power switch off. Wait at
least five seconds. Turn power
switch on.
If there is a “rC” or “bC” error:
3) Check control board MdB
harness.
Card Reader
Most recent “non-
transient error” from the
card reader.
No test available.
Refer to card reader manual
for corrective action.
Refrigeration
Temp Sensor
The temperature
sensor is defective or
unplugged.
Check to see that temperature
sensor harness is plugged into
door harness at air dam area.
If the sensor is unplugged,
replug it.
Check for temperature sensor
connection J7 on control board
is plugged in.
Compressor
System has failed to
decrease temperature
1° per hour while the
compressor is running.
Access relay mode (refer to
programming manual).
Check to see that the
refrigeration harness is
connected to the power
distribution panel. If they
are, refer to the refrigeration
troubleshooting flow chart on
the following pages.
Check refrigeration settings
(refer to refrigeration section of
programming manual).
Change settings as required.
Heater
Heater system has failed
to increase temperature
1° per hour while heater
is on.
Heater circuit not properly wired. Check electrical connections.
Bad sensor on heater circuit.
Replace sensor.
Defective heating element.
Replace heating element.
Miscellaneous Problems
Door Switch
Outer door has been
open for more than one
hour.
Check the vendor’s door switch
to see if it’s sticking or miswired.
Replace the door switch, if
defective.
Ram Error
Ram check sum for
service mode settings
stored in non-volatile
memory has been
corrupted.
No test available.
If error shows up frequently,
replace the control board.
AC Low
AC voltage to the
controller is less than
20Vrms for more than 30
seconds.
Check for low voltage at the wall
outlet at unit start-up.
Contact a qualified electrician.
Scale
Scaling Factor error - one
of the credit peripherals
has introduced a
scaling factor that is
not compatible with the
current configuration.
Check the connections of
changer harness; make sure
changer is plugged in and
working.
Make corrections to harness
or replace the changer if
necessary.
Summary of Contents for VARI-PAK 450
Page 2: ...TC 1 07 2003 PARTS AND SERVICE MANUAL VARI PAK...
Page 5: ...S 1 07 2003 SAFETY SECTION VARI PAK...
Page 8: ...S 4 07 2003 FIGURE 1...
Page 20: ...S 16 07 2003 NOTES...
Page 21: ...G 1 07 2003 GENERAL INFORMATION SECTION VARI PAK...
Page 28: ...G 8 07 2003 NOTES...
Page 29: ...CL 1 07 2003 CLEANING INFORMATION SECTION VARI PAK...
Page 32: ...CL 4 07 2003 NOTES...
Page 33: ...PG 1 07 2003 14 1 PROGRAMMING SECTION VARI PAK...
Page 57: ...C 1 07 2003 CABINET PARTS SECTION VARI PAK...
Page 59: ...C 3 07 2003 HARDWARE LIST...
Page 60: ...C 4 07 2003...
Page 61: ...C 5 07 2003...
Page 62: ...C 6 07 2003...
Page 64: ...C 8 07 2003...
Page 66: ...C 10 07 2003...
Page 68: ...C 12 07 2003...
Page 70: ...C 14 07 2003...
Page 72: ...C 16 07 2003...
Page 75: ...C 19 07 2003 NOTES...
Page 76: ...D 1 07 2003 DOOR PARTS SECTION VARI PAK...
Page 77: ...D 2 07 2003...
Page 79: ...D 4 07 2003...
Page 81: ...D 6 07 2003...
Page 83: ...D 8 07 2003...
Page 85: ...D 10 07 2003...
Page 87: ...D 12 07 2003...
Page 89: ...D 14 07 2003...
Page 91: ...D 16 07 2003 NOTES...
Page 92: ...M 1 07 2003 MAINTENANCE SECTION VARI PAK...
Page 98: ...M 7 07 2003 FIGURE 2...
Page 100: ...M 9 07 2003 NOTES...
Page 101: ...T 1 07 2003 TROUBLESHOOTING SECTION VARI PAK...
Page 112: ...T 12 07 2003 NOTES...