CONNECTION HARNESS

                                                                                                                                                   

1 - 2 : TAMPER N.C. (Tamper Switch Normally Closed Contact)

A normally closed dry contact while the front cover is secured on the main box. It is open while the cover is 
separated from the box. Connect this N.C. terminal to the 24 hour protection zone of an alarm system if necessary.

3 - 4 : DOOR BELL (Output Relay Contact for Door Bell)

It is a Normally Open (N.O.) relay dry contact with maximum rating of 24VDC/1Amp. It is prepared as a triggering 
contact of a low voltage door chime. The contact point keeps close as long as the bell button on the keypad is 
pressed.

5 - 6 : 12V DC (Power Input Terminal)

Connect to 12V DC power supply. The (-) supply and the (-) GND are the common grounding points of the system. 

7 : EG IN ( Egress Input)

A Normally Open (N.O.) input terminal referring to (-) ground. With the help of connecting a normally opened button 
to activate Output 1 for door opening in the same manner of using the Group 1 User PINs or Cards.
Egress button is usually put inside the house near the door. More than one egress buttons can be connected in 
parallel to this terminal. Leave this terminal open if not used. 
See Programming Location 90 for more information about the Egress Button with other features.

8 : GND (-) (Common Ground)

A common grounding point of the keypad

9 : DATA I/O (Data Input/Output Port for Split-Decoded Operation)

A data bus for signal communication with the optional Access Controller in Split-decoded operation. 
See "THE APO I/O PORT" Section for the details.

7

THE WIRE HARNESS

HAA2890_Manual.indd   15

24/05/2012   15:21:13

Summary of Contents for HAA2890

Page 1: ...DUAL RELAY DIGITAL ACCESS CONTROL READER KEYPAD WEATHERPROOF HAA2890 Programming Installation Manual FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS HAA2890_Manual indd 3 24 05 2012 15 21 11 ...

Page 2: ...ing And Operation Visitor Codes For Output 1 Only Configuration of The Output Modes for Output 1 Personal Safety And System Lock Out User PIN Entry Mode Pacifier Tones On Off Selection Output Operation Announcer Status LED Flashing On Off during Standby Intelligent Egress Button An Unique Feature of A Contemporary Keypad Where And Why Going Out Needs Attention Egress Delay and Warning Configuratio...

Page 3: ...glich Entsorgung Lesen Sie diese Bedienungsanleitung vor Inbetriebnahme sorgfältig durch IN DE HANDLEIDINGEN To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment Do not dispose of the unit or batteries as unsorted municipal waste it ...

Page 4: ...rial timer with the timing of 1 second to over 24 hours for Automatic Operator systems The unit is designed for surface mounting on wall or door frame The two relay outputs are coming with N C and N O Contacts for Door strike and N O Contact for Door Bell FEATURES A Member of The Tri Tech Series Keypads Compatible with The APO Access Controller DA 2800 or DA 2801 Durable Epoxy Coated Back lit Key ...

Page 5: ...ard Reading 10 seconds waiting for next digit entry 30 seconds waiting for code entry after card reading The Timer 1 99 999 Seconds Over 24 Hours possible Programmable Timer for O P 1 Egress Button Programmable for Instant Delay with Warning and or Alarm Momentary or Holding Contact for the Exit Delay Output Contact Ratings Output Relay 1 N C N O dry contacts 2A 24VDC Max Door Bell Relay N O dry c...

Page 6: ...HAA2890_Manual indd 12 24 05 2012 15 21 13 ...

Page 7: ... the common grounding points of the system 7 EG IN Egress Input A Normally Open N O input terminal referring to ground With the help of connecting a normally opened button to activate Output 1 for door opening in the same manner of using the Group 1 User PINs or Cards Egress button is usually put inside the house near the door More than one egress buttons can be connected in parallel to this termi...

Page 8: ...ivation INHIBIT RED It lights up while the output is inhibited THE PACIFIER TONES THE LED SIGNALS The buzzer and the amber LED indicator give following tones and signals respectively for system status STATUS TONES LED SIGNALS 1 On Programming Mode ON 2 Successful Key Entry 1 Beep 1 Flash 3 Successful Code Card Entry 2 Beeps 2 Flashes 4 Unsuccessful Code Card Entry 5 Beeps 5 Flashes 5 Power Up Dela...

Page 9: ...harged 2 Swich ON power again The system is in Power up Mode for 1 minute and the buzzer gives beeps during the whole period This is the only time limit for setting the system to Direct Access to Programming DAP 3 Press the Egress Button EG IN once first to enable the DAP function 4 Key in the DAP Code 8 0 8 0 and validate it with the existing Master Code in the memory is erased and the power up b...

Page 10: ...e 0 0 0 0 Factory Set Not a default value 0 2 Super User PINs Nil User Program Required 0 3 Common User PIN 1 Nil User Program Required 1 0 User PINs Cards for O P 1 Nil User Program Required 4 0 Visitor Codes Nil User Program Required 5 1 O P Mode of The O P 1 Time 5 Sec Momentary 6 0 Personal Safety Lock out Code 1 10 False Code Card Lock out 60 Sec 7 0 User Code Entry Mode Code 2 Manual Entry M...

Page 11: ...Output 1 for Door Open a b c d e a 10 Programming Location for Output 1 b 1 Programming option for EM Card only c 001 One of the 1 000 User IDs for the User PIN Card from 000 999 d Read Card Put the Card close to the card reader e Confirm the card is read 2 beeps 4 Set an User PIN to Operate The Output 1 for Door Open a b c d e a 10 Programming Location for Output 1 b 2 Programming option for User...

Page 12: ... 006 007 999 etc Total 1 000 users are allowed See Programming Location 10 for the details 7 Close The Programming Mode 2 beeps The programming mode is closed The keypad is back to normal operation mode OPERATION 8 Open The Door with The EM CARD 2 beeps the door is open 9 Open The Door with The User PIN 8321 2 beeps the door is open 10 Open The Door with The EM CARD User PIN 6123 2 beeps the door ...

Page 13: ...d a duplicate of the Prime Codes The system will reject a duplicated Prime Code for Secondary User PIN or vice versa e Getting Advantages from The Secondary User PINs The repeated Secondary PINs can be used as a Group Common User Code or called Department User Code for a group of EM Cards which simplifies the programming of using large number of different User PINs EM Card with Department Code pre...

Page 14: ...eration Example Set a Master Code with the number of 2 2 3 3 RECORD A SUPER USER PIN Location 02 The Super User PIN has TWO functions It is prepared for the owner to use it to operate the keypad under inhibit condition and make operation of inhibit enable disable to the system output SUPER USER PIN The Super User PIN can be 4 to 8 digits Two beeps will be heard after pressing the key to confirm co...

Page 15: ...PINs and Cards for Output 1 For safety reason the inhibit function initiated with the Super User PIN does not govern the Egress Button The door still can be opened with it from inside The function of the Super User PIN is not affected in the Inhibited Mode or Lock out Mode It is always a normal user code for Output 1 RECORD THE COMMON USER PINS FOR OUTPUT 1 Location 03 The Common User PIN is prepa...

Page 16: ...for each User PIN and or Card Repeated ID number will be rejected by the system ID Number 000 999for 1 000 User PINs Cards to operate Output 1 CARD OR USER PINS The User PINs can be 4 8 digits Key in the User PIN on each ID Number box then confirm it with key Just simply put the EM card close to the reader window to read it on each ID Number box then confirm it with key if it is a Card ONLY or Car...

Page 17: ...irm and store the Private User PIN into memory two beep confirms a valid entry ii Operation while the system is back to operation mode 1234 a b a Key in the Private User PIN 1 2 3 4 b Confirm it with the key Output 1 activates 3 Example 3 EM Card Secondary User PIN i Programming 10 3 003 24680 a b c d e f a The card is programmed for operating of the Output 1 b The operation is EM Card Secondary U...

Page 18: ... in 5 that is the Command Code for making a deletion here c Key in the User ID that stored the User PIN the lost EM card or the EM Card User PIN d Press the key Two beep confirms a valid entry and the PIN and or Card in that User ID is cleared ii Delete an EM Card 10 5 a b c d a Key in the User Group that the EM Card belongs to 1 0 for the Group 1 This keypad has user Group 1 only b Key in 5 that ...

Page 19: ...isitor Code is put in the same Code box the old code is replaced The Visitor Codes can be 4 8 digits for the Manual Mode code entry The Visitor Codes MUST be in the same digit length with the Master Code for Auto Mode code entry NOTE All Visitor Codes will be cleared after power down to prevent extension confusion of their valid time limit EXAMPLES Example 1 Set a One Time Visitor Code with the nu...

Page 20: ...9 seconds The output will reset automatically when the time expires OR it can be RESET manually at anytime with the Super User Code before the end of the time Example Reset Output 1 1 Output 1 resets PERSONAL SAFETY AND SYSTEM LOCK OUT Location 60 SAFETY LOCK OUT OPTIONS The Options are represented by their Mode Numbers in programming They are described below 1 After 10 successive false Card User ...

Page 21: ...N for code checking The User PINs can be 4 8 digits arbitrary and they are NOT required to be in the same digit length of the Master Code Manual Entry increases the level of security in the code trial by the unauthorized people PACIFIER TONES ON OFF SELECTION Location 71 PACIFIER TONES ON OFF MODES The Pacifier Tone is the Beep Tones from the keypad which include the tones of Successful Key entry ...

Page 22: ... Short Beeps Notification 2 short beeps notification is given when the output is activated with a valid Card Code STATUS LED FLASHING ON OFF DURING STANDBY Location 73 STANDBY FLASHING ON OFF Some people find the flashing light of the status LED the amber LED is annoying during the keypad is on standby especially at the night time The standby flashing can be ON OFF with the setting here 1 Standby ...

Page 23: ...the egress button with holding contact for the delay even gives higher level of security to a controlled door Kindergarten Young children are always active Some of them may be willing to go out to explore their ways of playing For safety reason teachers have to watch all of them in the attended area Leaving school alone without the companion of parents or teacher is dangerous to the young children...

Page 24: ...SS DELAY TIMER 0 No Delay Default Output 1 activates instantly the door is released instantly when the Egress Button is pressed 1 99 Egress Delay Timing Put any number of 1 to 99 into the box to enable the Egress Delay The number is the time in second which starts to count when the Egress Button is pressed Output 1 activates the door is released when the delay time reaches NOTE 1 Momentary Contact...

Page 25: ...n Example 3 Set Egress Button in Momentary contact without delay This is the default setting 90 1 0 a b c d a Egress function programming b Momentary contact without delay c Release door instantly d Entry confirmation CLOSE THE PROGRAMMING MODE Always close programming mode with to set system back to normal Operation after programming VALIDATION System is back to normal operation mode HAA2890_Manu...

Page 26: ...t least one Master keypad and one Access Controller to work 3 Slave Keypad of Split Decoded Mode No feature data is transferred to the Access Controller decoder from the Slave keypad It takes the same feature data from the Master keypad to operate The Slave keypad s is for a Split Decoded system that needs more than one keypads for operation convenience NOTE a Do not set more than one keypads in M...

Page 27: ...eypad s role is just a card reader and or a keyboard for code entry The link up of the two units is very simple It is just one wire The White Wire for the I O ports and a common grounding wire The Black Wire for the two units The I O port provides the data in the proprietary APO format It ONLY works with the DA 2800 The Optional DA 2800 Controller Introduction The DA 2800 controller unit is compat...

Page 28: ...or O P 1 OUTPUT MODE TIME 0 Start Stop 1 99999 Seconds Momentary 51 O P MODE TIME 5 Seconds 6 0 Personal Safety Lock out LOCK OUT CODE 1 10 Trial Lock out 60 Sec 5 10 5 10 Trial Lock Out 15 Minutes 00 No Lock out 60 LOCK OUT CODE Code 1 10 Trials Lock out 60 Seconds 7 0 PIN Entry Mode ENTRY MODE 1 Auto Mode 2 Manual Mode 70 ENTRY MODE Mode 2 Manual Mode 7 1 Pacifier Tone ON OFF FUNCTION MODE 0 OFF...

Page 29: ...em in Programming Mode 9 9 9 9 REFRESH CODE Refresh the system and set all its function back to default values 9999 All programmed data are cleared and back to the default values except the Master Code 8 0 8 0 DAP CODE Direct access to programming mode Valid only in the power up delay period 8080 System in Programming Mode 0 9 9 9 USER PINs Codes Cards whole group clearance Code Key in the Code to...

Page 30: ...quired if the electric lock is AC operated To avoid Electro Static Discharge from interfering with the operation of the keypad always ground the terminal of the keypad to earth 12V DC POWER SUPPLY AD 1312 OR AP 960 ELECTRIC LOCK N O N C OR CATHODE 1N4004 OUTPUT RELAY N O Output for Fail secure Lock N C Output for Fail safe Lock EGRESS BUTTON MORE EGRESS BUTTONS CAN BE CONNECTED IN PARALLEL N O N O...

Page 31: ...e of an alarm system if required The connection of the Door Bell is optional The door bell contact on the keypad is prepared for triggering of an low power door chime only DO NOT use it as a high voltage power path for a door bell The maximum power rating of the contact is 24V DC 1 Amp A TAMPER N C B DOOR BELL N O ORANGE PURPLE 3 4 DOOR BELL CONTACT N O ELECTRONIC DOOR CHIME OPTIONAL N O DOOR BELL...

Page 32: ...u Concerning Co ect to a 24 mon ginal date of pu e an article with complaint is va enses are out of article or a refun irst year after th rchase price or n the second yea used after delive by the article a essories that ar ble non rechar ited list damage lightni gently or resultin contrary to the l professional o months when th ropriate packing on repair or alt delivered to you ing and be com nd t...

Page 33: ......

Page 34: ......

Reviews: