6) Record an “EM Card + Commom User Code” to Operate The Output 1 for Door Open
10
4
004 #
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 4 = Programming option for EM Card + Common User Code
(c) 004 = One of the 1,000 User IDs for the User PIN/Card from 000-999
(d) Read Card = Put the Card close to the card reader
(e) # = Confirm the card is read, 2 beeps, the Common User Code goes to this User ID automatically
(f) A Common User Code (for example: 8 6 2 5)
MUST
be set at the Programming
Location 03
first for this operation
mode. The code can be used for all the EM Cards in this operation mode.
REMARK:
If more User PINs and Cards are required for Output 1, repeat the procedures (3) , (4) , (5) or (6) above with other User
IDs, such as 005, 006, 007 --- 999 etc. Total 1,000 users are allowed. See Programming Location 10 for the details.
7) Close The Programming Mode
---- 2 beeps
The programming mode is closed. The keypad is back to normal operation mode
OPERATION
8) Open The Door with The EM CARD
---- 2 beeps, the door is open
9) Open The Door with The User PIN
8321
#
---- 2 beeps, the door is open
10) Open The Door with The EM CARD + User PIN
6123
#
---- 2 beeps, the door is open
11) Open The Door with The EM CARD + Common User Code
8625
#
---- 2 beeps, the door is open
REMARK:
In the next Section, “KEY IN AND STORE THE DESIRED VALUES” describes all the features and functions of the system
in detail. Users can follow them to tailor the desired values for their access control systems. Suggest the general users
also spend some time on them to get acquaint with this powerful system for future expansion.