![Vector Revolution 180 Operating Manual Download Page 113](http://html1.mh-extra.com/html/vector/revolution-180/revolution-180_operating-manual_4558578113.webp)
Run
9
________________________________________________________________________________________
_______________________________________
9
-
60
9.3.1 Advanced Controls: Glue
These settings are:
Set Temp
Comb
Set temperature for the comb (cartridge) element
Nozzle
Set temperature for the nozzle element
Actual Temp Comb
Display of the actual comb temperature
Nozzle
Display of the actual nozzle temperature
Glue Start 360 (0.1mm)
Distance from tape present switch to glue start. Increasing this
distance moves the glue away from the leading edge of the
band for a 360 degree panel.
Glue Stop 360 (0.1mm)
Distance from when the end of the band falls off the tape
present switch to when the glue turns off. Reducing this count
moves the glue finish away from the trailing edge of the band
Glue Start non-360
Distance from tape present switch to glue start. Increasing this
distance moves the glue away from the leading edge of the
band for a 360 degree panel. For thin tapes, it can be
advantageous to allow the band under the 1
st
pressure roller
before starting glue so it pulls the band across the nozzle.
Glue Stop non-360
Distance from when the end of the band falls off the tape
present switch to when the glue turns off. Reducing this count
moves the glue finish away from the trailing edge of the band
Summary of Contents for Revolution 180