Shrink Tank VC999 85.47i
Page 18/34
Art. no. 512.320
2009-11-17
8.3 Water Connection
The VC999 85.47i Shrink Tank can be fed with cold or
warm water.
NOTICE
With hard water it is desirable to install a water softener
in the water supply line. This reduces lime deposits and
minimises cleaning.
For the water-pressure a manometer and a regulating
tap should be provided on site.
To clean the filter (38) the Shrink Tank must be
disconnected from the water supply by means of a
stopcock.
Clean the filter 1 day after first start-up according to
Section 13.1.2.
Water connection from above: Connect by flexible
hose to item 35, threaded joint R½“.
Fig. 6
Water connection from below:
•
Take down back panel on right.
•
Remove cover cap (36), screw on to upper
connection (35) and tighten.
•
Connect by flexible hose to bend (37).
•
Replace back panel.
NOTICE
When installing take care that no impurities get into
the supply line and that the water unit is not twisted
when tightening.
8.4 Steam Connection
Only for versions with steam heating:
NOTICE
A manometer (setting 6 bar max) and a safety value
set for 8 bar must be provided on site. To clean the
filter (40) it must be possible to isolate the shrink tank
from the steam supply with a steam valve.
WARNING
Risk of scalding from the discharge of hot steam!
Steam connection from above:
•
Connect steam supply to tube (39) (R½“).
Steam connection from below:
•
Take down back panel on right.
•
Remove tube (39).
•
Mount plug (41) on opposite side as seal.
•
Connect steam supply to bottom of T-piece (42)
(R½“).
•
Replace panel.
Fig. 7
8.5 Installing Steam Exhaust Pipe
The joint opening for the steam exhaust tube is
arranged for an outside tube diameter of 160 mm (Fig.
1, item) (of chapter 4 in Technical Data).
Take care when installing the steam drain line that too
much condensate cannot run back into the Shrink
Tank (provide siphon with drain opening).
Summary of Contents for 85.47i D
Page 4: ......
Page 21: ...Shrink Tank VC999 85 47i 2009 11 17 Art no 512 320 Page 21 34 Flow chart for program Level...
Page 23: ...Shrink Tank VC999 85 47i 2009 11 17 Art no 512 320 Page 23 34 Decalcifying program...
Page 24: ...Shrink Tank VC999 85 47i Page 24 34 Art no 512 320 2009 11 17 Flow chart ABC level...
Page 32: ...Shrink Tank VC999 85 47i Page 32 34 Art no 512 320 2009 11 17 16 Pneumatics diagram...
Page 33: ...Shrink Tank VC999 85 47i 2009 11 17 Art no 512 320 Page 33 34 17 Circuit diagrams...
Page 34: ...Shrink Tank VC999 85 47i Page 34 34 Art no 512 320 2009 11 17...